4.3
Cooling mode
This mode is selectable only if the heating/cooling installation is ready for operation in Cooling
mode (cooling floor, fan coils, etc.) and the heat pump is configured for this purpose.
In this operating mode, the
DUAL CLIMA
heat pump will cool and keep the water in the
heating/cooling installation at the desired temperature. To do this, select the desired cooling
temperature setpoint (see
"Temperature Selection"
) and the temperature of the room thermostat (if
any) (see
"Operation with Room Thermostat"
).
This mode will operate
only
on the heating/cooling installation, disabling the DHW production
service, if any.
4.4
Heating mode
In this operating mode, the
DUAL CLIMA
heat pump will heat and maintain the water in the
heating/cooling installation at the desired temperature. To do this, select the desired heating
temperature setpoint (see
"Temperature Selection"
) and the temperature of the room thermostat (if
any) (see
"Operation with Room Thermostat"
).
This mode will operate
only
on the heating/cooling installation, disabling the DHW production
service, if any.
4.5
DHW mode
This mode will be selectable only if the installation has a Domestic Hot Water tank connected and
the heat pump is configured for it.
In this operating mode, the
DUAL CLIMA
heat pump will heat the domestic water of the DHW tank
up to the desired temperature, allowing Domestic Hot Water service to the home. To do this, select
the desired DHW setpoint temperature (see
"Temperature Selection"
). Once the desired temperature
has been reached, the heat pump will stop and wait to receive the DHW demand.
This mode will operate
only
on the installation of the DHW tank, disabling the heating and/or
cooling installation of the heating/cooling installation.
4.6
AUTO and DHW mode
+
This mode will be selectable only if the heating/cooling installation is ready to operate in Cooling
mode (cooling floor, fan coils, etc.); the installation has a connected domestic hot water tank and
the heat pump is configured for it.
This operating mode is the combination of the AUTO and DHW modes simultaneously. When the
DHW demand is enabled, the heat pump will disable the heating or cooling service and enable the
Hot Domestic Water production mode, with the production of priority DHW relating to the heating
or cooling of the heating/cooling installation. Once the desired DHW temperature is reached, the
heat pump will re-enable automatic heating or cooling of the installation (see
"AUTO Mode"
).