DOMUSA TEKNIK FUSION COMBI F 80 Скачать руководство пользователя страница 1

FUSION COMBI W 50 
FUSION COMBI F 80 

HYBRID MODULE 

 

EN 

| INSTALLATION AND OPERATING INSTRUCTIONS 

Содержание FUSION COMBI F 80

Страница 1: ...FUSION COMBI W 50 FUSION COMBI F 80 HYBRID MODULE EN INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...of this appliance should be carried out only by qualified personnel in accordance with the regulations in force and following the manufacturer s instructions Both the start up and any maintenance operation of this appliance should be carried out only by the Official Technical Assistance Services of DOMUSA TEKNIK Incorrect installation of this product may cause damage to people animals and objects ...

Страница 3: ... pumps of the installation BC BF 15 3 5 2 Connecting the module with the DUAL CLIMA R heat pump and the boiler 15 3 5 3 INSTRUCCIÓN DE CONEXIÓN ELÉCTRICA CON UNA CALDERA CON MANTENIMIENTO DE TEMPERATURA MÍNIMA DE CALDERA 17 3 6 CONNECTING ROOM THERMOSTATS 18 3 6 1 Connecting a 3 wired switched room thermostat for Heating Cooling 18 3 6 2 Connecting two room thermostats one for heating and the othe...

Страница 4: ...e DANGER Warns of operations or situations of imminent danger which if not avoided can cause severe injury or even death 1 2 Other symbols The following symbols are used in instructions to draw attention to important information NOTE Indicates the risk of breakdown and damage to property or people ATTENTION Indicates important additional information that may be related to the correct operation of ...

Страница 5: ... complete In case of doubt do not use the appliance and refer to the supplier Keep the packaging elements out of reach of children as they can be dangerous Improper installation or placement of equipment or accessories may cause electrocution short circuit leakage fire or other damage to the equipment Use only accessories or optional equipment manufactured by DOMUSA TEKNIK and specifically designe...

Страница 6: ...3 Heating cooling flow circuit 1 4 Heating cooling Flow circuit 2 5 Drain drain socket 6 Heating cooling return circuit 1 7 Heating cooling return circuit 2 8 Return to boiler 9 Return to DUAL CLIMA R Heat Pump 10 Inlet from boiler 11 Entrance from DUAL CLIMA R Heat Pump 12 DUAL CLIMA R Heat Pump control panel 13 Boiler only operation switch 14 Connection strip ...

Страница 7: ...ting cooling pump circuit 1 5 DUAL CLIMA R Heat Pump control panel 6 Boiler only operations switch 7 Heating cooling Flow circuit 1 8 Inlet from boiler 9 Entrance from DUAL CLIMA R Heat Pump 10 Heating cooling Flow circuit 2 11 Return to boiler 12 Heating cooling return circuit 1 13 Return to Heat Pump DUAL CLIMA R 14 Heating cooling return circuit 2 ...

Страница 8: ...alled in combination with a heat pump from the DUAL CLIMA R line supplied by DOMUSA TEKNIK and an existing heating boiler Therefore for their operation these devices should be connected to each other both hydraulically and electrically In this section the necessary operations for said connection are described in detail ...

Страница 9: ...stacle that makes such access impossible Wall fixing system Although the FUSION COMBI W 50 module is supplied from the factory foreseeing its installation with the DUAL CLIMA R heat pump and boiler outlets from the top the FUSION COMBI W 50 module can be mounted with said outlets on the bottom of the module To do this the module has hangers at both ends Once the module is hung on the wall if neces...

Страница 10: ...lation and on the return branch of the machine with water to avoid the entry of dirty water into the heat exchanger condenser It is recommended to insert this filter between two cut off valves in order to be able to clean it without emptying the installation The type of filter installed must be adapted to the particular characteristics of each installation type and material of the water pipes type...

Страница 11: ...45ºC and the other with radiators ATTENTION The flow and return outlets of the DUAL CLIMA R heat pump and the boiler must be hydraulically connected to the FUSION COMBI module in the corresponding outlets indicated on the module see diagram ATTENTION For the installation of an underfloor heating circuit it is essential to install a temperature limiter or a mixing valve at a temperature 45ºC at the...

Страница 12: ...inside the heat pump and must be mounted on the front of the FUSION COMBI hydraulic module To do this open the module door and access the remote control support located on its back For its correct assembly carefully follow the following steps 1 Open the front cover of the FUSION COMBI module using a flat screwdriver to make a slight lever 2 Rest the front cover of the FUSION COMBI module on a tabl...

Страница 13: ...ficiently long cable length must be provided inside the module in such a way that it is possible to open the front of the equipment without having to disconnect said cable and facilitate any maintenance operation inside 6 Before starting the heat pump the control panel must be connected to the external machine To do this pass the cable supplied inside the heat pump located together with the probe ...

Страница 14: ...can be extended up to a maximum distance of 100 metres section between 0 5 1 25 mm2 DANGER While working on the system Be sure to disconnect both the module and the heat pump from the electrical supply To do this you can disconnect the supply from the main network checking that boththe FUSION COMBI hydraulic module and the heat pump are completely disconnected ATTENTION Provide enough length of ca...

Страница 15: ...t pump to the electrical supply as indicated in the Connection to the general electrical supply section of the DUAL CLIMA R heat pump manual DANGER Whenever working on the electrical installation make sure that both the module and the DUAL CLIMA R heat pump are disconnected from the mains 3 5 1 Connecting the circulation pumps of the installation BC BF The FUSION TRIO hydraulic module can manage t...

Страница 16: ...to the equipment Subsequently connect with two cables the E2L and N connection terminals of the DUAL CLIMA R heat pump terminal strip with terminals 15 and 16 of the terminal strip inside the FUSION COMBI module see Wiring diagram Finally interconnect the input terminals of the existing boiler room thermostat with the connection terminals No 10 and 11 TAcald of the FUSION COMBI module terminal str...

Страница 17: ...CLIMA R heat pump are disconnected from the mains 3 5 3 Instruction on electrical connection to a boiler with minimum boiler temperature maintenance If you have a boiler with minimum temperature maintenance and you only want it to be on when the heat pump needs it as support or auxiliary the electrical connections must be made as follows ...

Страница 18: ...these configurations In turn through terminals 12 13 and 14 of the terminal strip the thermostat signals can be connected to the DUAL CLIMA R outdoor unit In this way the operating modes of the the heat pump from the place where the installed room thermostats are located Through terminals 12 13 the Cooling mode will be activated and deactivated and through input 12 14 the Heating mode will be acti...

Страница 19: ...19 FUSION COMBI W 50 FUSION COMBI F 80 DANGER Whenever working on the electrical installation make sure that both the module and the DUAL CLIMA R heat pump are disconnected from the mains ...

Страница 20: ...erature The FUSION COMBI module will manage the activation of each circulation pump BC or BF corresponding to each Heating or Cooling mode as follows As indicated in the figure in case of selecting the setpoint temperatures of the room thermostats in such a way that both demand operation simultaneously the control of the hydraulic module will start operation in the Manual mode that is both circula...

Страница 21: ...l be necessary to select the operating mode both in the thermostat and in the heat pump For this room thermostat management to function correctly the heat pump and the thermostat must be configured for the same and only operating mode Heating or Cooling ATTENTION Check that for this room thermostat management to function correctly the heat pump and the thermostat must be configured for the same an...

Страница 22: ...om thermostat should be prepared for this purpose The thermostat connected to the cooling input CRT should demand closed circuit signal when the room temperature is higher than the desired temperature setpoint temperature and in turn the thermostat connected to the heating input HRT should demand closed circuit signal when the room temperature is lower than the desired temperature setpoint tempera...

Страница 23: ...position 1 select the desired operating mode heating or cooling from the DUAL CLIMA R heat pump control panel menu Once it has been ensured that parameters P54 and P55 are in position 1 select the desired operating mode heating or cooling from the DUAL CLIMA R heat pump control panel menu Parameter P56 of the DHW service must be deactivated position 0 This service is not available with the FUSION ...

Страница 24: ...ump BF Cooling mode circulating pump TAC Heating mode room thermostat TAF Cooling mode room thermostat N DC Heat pump DUAL CLIMA R common signal Neutral E2 Heating support signal input E2 from heat pump DUAL CLIMA R R Relay TACALD Connection at the terminals for the boiler room thermostat IEC Boiler only operation switch ...

Страница 25: ...25 FUSION COMBI W 50 FUSION COMBI F 80 6 DIAGRAMS AND MEASUREMENTS FUSION COMBI W 50 ...

Страница 26: ...M EIC 1 H 3 4 M RRC 1 H 3 4 M IC 1 H 3 4 M RC 1 H 3 4 M IBC 1 H 1 H RBC 1 H 1 H IC Heating Cooling Flow circuit 1 RC Heating Cooling Return circuit 1 IBC Heat Pump Flow RBC Heat Pump Return IC Heating Cooling Flow circuit 2 RC Heating Cooling Return circuit 2 EIC Support boiler Flow for Heating RRC Return of the backup boiler for Heating ...

Страница 27: ...27 FUSION COMBI W 50 FUSION COMBI F 80 NOTES ...

Страница 28: ...f any kind to its product characteristics without prior notice www domusateknik com POSTAL ADDRES FACTORY OFFICES Apartado 95 Bº San Esteban s n 20730 AZPEITIA 20737 ERREZIL Gipuzkoa SPAIN Telf 34 943 813 899 Fax 34 943 815 666 CDOC002478 CDOC002478 28 07 21 ...

Отзывы: