Installation Instructions

SDF100

Low Voltage

(SELV) Axial Fans

OPERATIONS
TIMER ADJUSTMENT on SDF 100TBLV

Isolate the power supply. Remove the transformer cover. The timer adjustment is clearly marked. Turn the adjuster anti-clockwise to reduce 
the over-run time and turn clockwise to increase the over-run time. The approximate range of the timer is 2 minutes to 30 minutes.

TIMER ADJUSTMENT on SDF 100HTBLV

Isolate the power supply. Remove the fan cover. The timer adjuster is situated at the right hand side. Turning the adjuster clockwise will 
increase the over-run time. The approximate range of the timer is 2 minutes to 30 minutes.

HUMIDITY ADJUSTMENT on SDF 100HTBLV

Isolate the power supply. Remove the front cover of the fan and the adjustment of the humidity control is done using a fine tipped 
screwdriver. Turn adjuster clockwise for less sensitivity and anti-clockwise for increased sensitivity. Adjustment is from 50% RH and 
the range is approximately 50% to 90% RH. Condensation/Humidity controls are designed to switch an extractor fan on when the room 
humidity exceeds a pre-set level. In order to achieve this the humid air must invade the sensor housing. This process can take some 
time and when the room is in use this delay may cause some concern, also the sensor cannot detect smells or smoke. Therefore, we 
recommend that fans with humidity controls should be wired up with manual (switch live) operation.

FITTING WINDOW FAN (Using SDF901WFK)

1.  Cut hole in window 127mm (5”)min. size 140mm (5

1

/2”) max size - 

this is probably a job for a glazier.

2.  Remove the four fan clamp screws holding the inside and outside 

halves together.

3.  Hold the cowl on the outside of the window and insert the fan into the 

hole from the inside, making sure not to displace the weather seal in 

the process.

4.  Replace the fan clamp screws and tighten evenly.

NOTE:

   

Do not over-tighten as this may break the glass.

MAINTENANCE
Isolate from power supply before commencing work.
TRANSFORMER

Maintenance free but the outer cover may be cleaned with a damp cloth.

FAN

The outside of the unit may be wiped clean with a damp cloth. Once a year 

the front cover should be removed and the inside dusted with a soft brush.

NOTE:

If the fan unit is fitted to an uneven surface 
such as fluted glass it may be necessary to 
use some silicone bathroom sealer to ensure 
that the discharge cowl is weather-proof.

Transformer

Input 

230v   AC ~ 50Hz

Output 

12v  AC ~ 42VA

Fan Unit

CLAMP SCREW
FITTINGS

WEATHER PROOF
SEAL. (See note 
above if used or 
uneven surface)

WARNING: 

Failure to comply with these instructions may invalidate the warranty. If room is fitted with an unbalanced 
gas appliance, ensure that there is enough replacement air for both gas appliance and extract fan.

CAUTION: 

Fans incorporating electronic control systems may be damaged if used in conjunction with fluorescent lamps. 
If in doubt, we recommend you contact our customer services department on 03443 715523.

ISSUE 3

09/17  LAB995R

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety

.