CMX-S

Installation Instructions

Central Mechanical Extract Ventilation (cMEV) appliance 

1.0 SAFETY INFORMATION

• 

DO NOT SWITCH OFF THE UNIT

 – it is designed to run continuously. If the unit is switched 

off, indoor pollutants and moisture levels may increase which could endanger your health or 
damage your home. It is important to follow the advice in this manual and correctly maintain the 
system to ensure a healthy indoor environment.

• 

All wiring must be in accordance with prevailing national regulations, for example the current 

IEE Wiring Regulations BS7671. The electrical installation should be inspected and tested by a 
suitably qualified person after completion. 

• 

The installer is responsible for the installation and electrical connection of this system on site. 

It is the responsibility of the installer to ensure that the equipment is safely and securely installed 
and left only when electrically and mechanically safe.

• 

When installing the appliance, care should be taken not to damage any hidden utilities.

• 

Ensure that the mains supply (Voltage and Frequency) complies with the rating label.

• 

Isolate from power supply before removing any covers. During installation / maintenance 

ensure all covers are fitted before switching on the mains supply. 

• 

The appliance should be provided with a local double pole fused spur fitted with a 3 Amp fuse 

and a minimum contact separation of at least 3mm. 

• 

This unit must be earthed.

• 

Ducting must be securely fixed with screws to the spigot to prevent access to live parts. Duct 

runs terminating close to the fan must be adequately protected by suitable guards.

• 

All regulations and requirements must be strictly followed to prevent hazards to life and 

property, both during and after installation and any subsequent servicing or maintenance.

• 

This appliance should not be used by children or persons with reduced physical, sensory or 

mental capabilities or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning the safe use of the appliance by a person responsible for their safety. 
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried 
out by children.

LAB964R  

|  

JAnuARy 2021

PAGE 1

Содержание CMX-S

Страница 1: ...den utilities Ensure that the mains supply Voltage and Frequency complies with the rating label Isolate from power supply before removing any covers During installation maintenance ensure all covers are fitted before switching on the mains supply The appliance should be provided with a local double pole fused spur fitted with a 3 Amp fuse and a minimum contact separation of at least 3mm This unit ...

Страница 2: ...measuring equipment to fit correctly over the valves Ducting should be insulated where it passes through unheated spaces and voids e g loft spaces to reduce the possibility of condensation forming 1 1 Hazard Symbols REFER TO INSTRUCTION MANUAL Read and understand the installation and maintenance manual before installing operating or maintaining this product 1 2 Important Information This manual co...

Страница 3: ...djustable at the wiring centre to facilitate Building Regulation commissioning speeds Manual LOW BOOST PURGE switch code ANC850A Manual BOOST and PURGE selection switches LOW speed is engaged upon connection of mains supply PURGE speed is intended to be higher than the BOOST Building Regulation commissioning speed and should be selected during periods when exceptional levels of indoor pollution ar...

Страница 4: ... should be fitted or a proprietary roof terminal designed for mechanical ventilation with a free area of at least 15175mm Further details regarding installation can be found in the 2010 Domestic Ventilation Compliance Guide 3 1 1 Rigid Ducting Install using the least number of fittings to minimise resistance to airflow All duct runs should be as short and as straight as possible for maximum perfor...

Страница 5: ...0R Wiring 8 5 2 ANC108A Overrun Timer ANC108A Wiring 9 5 3 ANC802A Humidistat With Timer ANC846A Humidistat With Timer And Remote Sensor ANC808A Humidistat With Pull Cord ANC801A ANC846A ANC808A Wiring 10 5 4 ANC813A PIR With Overrun Timer ANC813A Wiring 11 LAB964R January 2021 PAGE 5 ...

Страница 6: ...misused disassembled or not installed commissioned and maintained in accordance with the details contained in this manual and general good practice The above warranty does not apply to nor cover the repair of any problem or fault with the product which arises as a result of a failure to install operate maintain and or repair the product or any associated parts and components including any ducting ...

Страница 7: ... spares please quote the serial number of the unit together with the part number if the part number is not known please give a full description of the part required The serial number will be found on the identification plate attached to the unit casing Telephone 03443 715 523 vent technical domusventilation co uk Installer Contact Details Company Name Contact Tel Email LAB964R January 2021 PAGE 7 ...

Страница 8: ...ntilation co uk Tel 03443 715 523 www domusventilation co uk Technical or commercial considerations may from time to time make it necessary to alter the design performance and dimensions of equipment and the right is reserved to make such changes without prior notice LAB964R January 2021 PAGE 8 ...

Отзывы: