IO Signal
Enable this function, to adjust the pulse width of the output signal that is sent after printing is
done.
When the output is not active, the signal is high (24 V).
When the output is active, the signal is low (0 V).
The IO signal pulse width is illustrated in the diagram below:
To enable IO signal and adjust the output pulse width:
1. From the
Home
screen, select the
Settings
icon:
1.
2. Select the
Advanced Settings
icon:
2.
3. Turn
IO signal
On.
3.
4. Adjust the
Output Pulse width (ms)
value, to set the width of the output in milliseconds.
4.
INSTALLATION
80
EPT077343 EN - Issue 1 - 11 November 2022
Содержание G Series