PRINT HEAD PRODUCT DETECT SENSOR
CALIBRATION
To calibrate the print head's internal product detect sensor:
1. Put the print surface or a box in front of the print head so it covers the product detect
1.
sensor.
2. The sensor LED on the print head should turn on to indicate that the sensor is triggered.
2.
3. If the sensor LED did not turn on, use a small screw driver to turn the sensor adjustment
3.
screw on the print head clockwise until the sensor LED turns on.
4. Remove the print surface or box from in front of the print head.
4.
5. The sensor LED should now turn off. If the sensor LED did not turn off, turn the sensor
5.
adjustment screw anti clockwise until the sensor LED turns off.
INSTALLATION
EPT077343 EN - Issue 1 - 11 November 2022
55
Содержание G Series
Страница 1: ...G Series Product Manual G50i ...
Страница 42: ...7 Fit the print head 7 INSTALLATION 42 EPT077343 EN Issue 1 11 November 2022 ...
Страница 46: ...7 Fit another round bar 7 8 Fit the controller 8 INSTALLATION 46 EPT077343 EN Issue 1 11 November 2022 ...
Страница 104: ...2 Open the latch and remove the ink cartridge 2 OPERATION 104 EPT077343 EN Issue 1 11 November 2022 ...
Страница 117: ...Name Description Content Displays a preview of the database object OPERATION EPT077343 EN Issue 1 11 November 2022 117 ...
Страница 121: ...Name Description Content Displays a preview of the database object OPERATION EPT077343 EN Issue 1 11 November 2022 121 ...
Страница 167: ...MAINTENANCE TROUBLESHOOTING EPT077343 EN Issue 1 11 November 2022 167 ...
Страница 170: ...MAINTENANCE TROUBLESHOOTING 170 EPT077343 EN Issue 1 11 November 2022 ...
Страница 171: ...EPT077343 EN Issue 1 11 November 2022 171 ...