INSTALLATION INSTRUCTIONS
L025317 Issue 5 July 2014
2-43
Connection of Compressed Air to the Laser
WARNING:
Operating air pressure is 4 bar!
Connect the hose from the air installation kit to the laser compressed air
inlet.
A safety valve is at the air inlet. It opens if the air flow at the inlet exceeds
450lpm.
For safety reasons there are two separate outlets for compressed air. To
one of them a silencer is connected (Air Outlet 2). A hose is connected to
the other one (Air Outlet 1). The end of this hose has to be installed in a way
that it does not get blocked at any time or that water may infiltrate into the
hose. Please check the outlets for blocking and dirt on a regular monthly
basis. Blocked outlets may damage the laser!
One may check the function of the safety valve upon installation. Turn the
line pressure up to 3,5 bar to 4,5 bar until the safety valve opens. Reduce
the pressure by 01, bar to ensure the correct air flow. Please note that air
pressure is only applied to the safety valve if the switch valve inside the
laser head is open. If it is closed there is no air flow through the laser head.
Both air outlets must be kept clear. Only one silencer has to be installed to
the air outlets. Do not use silencers on both air outlets. Do not swap inlets
and outlets for compressed air.
Check the silencer for dirt once a year. Remove the stainless steel housing
to check the silencer.
Minimum inner diameter of the outlet hose must be 12 mm. The length of
the outlet hose must not exceed 4 metres.
Air Outlet 1 to connect
hose
Air Outlet 2 with silencer
Air Inlet
Safety valve
Содержание D120i Blue IP
Страница 1: ...Domino D Series Product Manual ...
Страница 3: ...L025317 Issue 5 July 2014 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ... 6 L025317 Issue 5 July 2014 ...
Страница 8: ... 8 L025317 Issue 5 July 2014 ...
Страница 9: ...L025317 Issue 5 July 2014 9 ...
Страница 20: ... 20 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 22: ...HEALTH SAFETY 1 2 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 40: ...HEALTH SAFETY 1 20 L025317 Issue 5 July 2014 Location of Controller signs Controller rear side E ...
Страница 41: ...HEALTH SAFETY L025317 Issue 5 July 2014 1 21 Location of Laser signs D Series 10 and 30 Watt heads ...
Страница 42: ...HEALTH SAFETY 1 22 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 58: ...INSTALLATION INSTRUCTIONS 2 16 L025317 Issue 5 July 2014 X2 Connector Schematic Beacons ...
Страница 70: ...INSTALLATION INSTRUCTIONS 2 28 L025317 Issue 5 July 2014 X23 Connector Schematic RS232 COM1 ...
Страница 104: ...INSTALLATION INSTRUCTIONS 2 62 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 109: ...OPERATION L025317 Issue 5 July 2014 3 5 ...
Страница 110: ...OPERATION 3 6 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 164: ...OPERATION 3 60 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 166: ...TECHNICAL REFERENCE 4 2 L025317 Issue 5July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 175: ...TECHNICAL REFERENCE L025317 Issue 5 July 2014 4 11 Dimensions D Series Control Unit 10W to 30W systems IP55 version ...
Страница 177: ...TECHNICAL REFERENCE L025317 Issue 5 July 2014 4 13 Dimensions D Series Control Unit 60W systems IP55 version ...
Страница 184: ...TECHNICAL REFERENCE 4 20 L025317 Issue 5July 2014 D Series Scanner Short Mount Orientations down left right ...
Страница 188: ...TECHNICAL REFERENCE 4 24 L025317 Issue 5July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 190: ...MAINTENANCE AND FAULT FINDING 5 2 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 216: ...MAINTENANCE AND FAULT FINDING 5 28 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 218: ...APPENDIX FONTS A 2 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 220: ...APPENDIX BARCODES B 2 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 224: ...APPENDIX BARCODES B 6 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...