INSTALLATION INSTRUCTIONS
The installation, servicing and gas installation must be performed by an authorised/qualified person. The refrigerator must be
installed in accordance with the manufacturers installation instructions, local gas fitting regulations, municipal building codes,
electrical wiring regulations, AS5601 “Gas Installations” and any other statutory regulations.
vENTILATION REqUIREMENTS
The installation shall be made in such a manner as to separate
the combustion system from the living space of the mobile
home or recreational vehicle. Proper installation requires one
lower fresh air intake and one upper exhaust vent.
We recommend fitting the Dometic ventilation system, which
is specially developed by Dometic for this purpose. The ven
-
tilation kits must be installed and used without modification.
An opening toward the outside at floor level in the refrigera
-
tor compartment must be provided for ventilation of heavier-
than-air fuel gases. The lower vent of the recommended kits
is provided with proper size openings. The flow of combus
-
tion and ventilating air must not be obstructed.
The lower side vent is fitted with a panel, which provides an
adequate access opening for ready serviceability of the burner
and control manifold of the refrigerator. This should be cen-
tred on the back of the refrigerator. For further information
contact your dealer or distributor.
ventilation heights
MINIMUM vENTILATION hEIGhTS (MM)
Installation with
upper and lower
side vent
Installation with
roof vent and lower
side vent
RM2453
1046
960
RM2553
1202
1130
CLEARANCES
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL (MM)
Top
G
0
Side
K
0
Bottom
L
0
Rear
M
1
0
1
The distance between the rearmost part of the refrigerator and the
wall behind the refrigerator.
G
K
K
L
M
M
Содержание RM2453 and
Страница 15: ...15 Appendix B wiring diagram...
Страница 16: ......