FIG. 8

THERMOCOUPLE

SCREW

RETAINER

THERMOCOUPLE
CONNECTION

BURNER
JET

TEST
PORT

CLEAR BLUE COLOR
OF FLAME

FIG. 9

REFRIGERATORS WITH AUTOMATIC REIGNITORS
(RM2552 & RM2553)
A. Start the refrigerator according to the instructions for

Gas Operation with Automatic Reignitor. See 

Section

B. Operating Instructions, Item 3, Gas Operation.

B. Check that the gas flame is lit by observing flame

indicator (E). (See FIG. 9).

C. Close the gas valve by turning the knob "A" back to the

"OFF" position. (See FIG. 9)

D. Wait one minute, then disconnect the 12 volt DC power.

(See FIG. 6 and 6A).

E. Remove burner cover plate. (See FIG. 6 and 6A). Open

the gas valve by turning knob "A" to the "GAS" position
without pushing button "C". (See FIG. 9). The reignitor
should not be sparking. Apply commercial leak-check
bubble solution to the burner jet. (See FIG. 8). Be
careful not to damage burner jet.

F. No bubbles should appear at the opening of the burner

jet. Bubbles indicate a defective gas safety shutoff and
service is required.

G. If no bubbles were present at the burner jet, rinse the

orifice with water. Replace the burner cover plate.
Reconnect the 12 volt DC power supply to the refrigera-
tor. See Section A. Installation, Item 11, 12 Volt DC
Connection. Start the refrigerator by following the in-
structions for gas operation with automatic reignitor.
Normal gas operation should now return. Allow the
burner to operate a minimum of five minutes.

! WARNING

DO NOT use a flame to check for leaks.

FIG. 10

10. 120 VOLT AC CONNECTION

The refrigerator is equipped with a three-prong (grounded)
plug for protection against shock hazards and should be
plugged directly into a properly grounded three-prong
receptacle. DO NOT cut off or remove the grounding prong
from this plug. The free length of the cord is 2 feet and
therefore recommended that the receptacle be located to
the left side of the refrigerator (viewed from the rear) and
approximately 6 inches from the floor. (See FIG. 10). This
allows easy accessibility through the vent door. The cord
should be routed to avoid contacting the burner cover, flue
cover, or any other components that could damage the
cord insulation.

Содержание RM2452

Страница 1: ...store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance REFRIGERATOR MODELS RM2452 RM2453 RM2552 RM2553 ABSORPTION REFRIGERATORS FOR LP GAS AND ELEC...

Страница 2: ...he combustion system from the living space of the mobile home or recreational vehicle Louver openings for air supply or for venting of combustion products shall have a minimum dimension of not less th...

Страница 3: ...ee NOTE NOTE Clearance M is between the rearmost part of the refrigerator and the wall behind the refrigerator NOTE Clearance N is the distance between the bottom of the lower vent to the roof materia...

Страница 4: ...frigerator must be installed in a substantial enclosure and must be level When installing the refrigerator in the enclosure all areas within the recess in which the refrigerator is installed must be s...

Страница 5: ...ear base See FIG 5D FIG 5D Failure to follow the sequence in securing the refrigerator in the enclosure can cause leakage between the frame and cabinet Hole for Drain Water Hose FIG 5C 8 GAS CONNECTIO...

Страница 6: ...s on the installation and con nection to the gas supply are required contact your dealer or distributor D Wait for one minute E Remove burner cover plate See FIG 6A Open the gas valve by turning knob...

Страница 7: ...ervice is required G If no bubbles were present at the burner jet rinse the orifice with water Replace the burner cover plate Reconnect the 12 volt DC power supply to the refrigera tor See Section A I...

Страница 8: ...t DC terminal block located on the back of the refrigerator DO NOT use the body or chassis of the vehicle as a substitute for either of the two conductors DO NOT connect any other electrical equipment...

Страница 9: ...ws SECTION B CERTIFIED VENT SYSTEM KITS REFRIGERATOR KIT MODEL NO COMPONENTS PART NO RM2452 OPTION 1 ROOF BASE 3103633 XXX RM2453 ROOF COVER 3103634 XXX RM2552 LOWER SIDE VENT 3102277 XXX RM2553 OPTIO...

Страница 10: ...nia downward by gravity through this section If the refrigerator isoperatedwhenitisnotlevelandthevehicleisnotmoving liquid ammonia will accumulate in sections of the evapora tor tubing This will slow...

Страница 11: ...tting of the Thermostat In gas operation the thermostat closes its main valve and the burner runs continuously at the bypass rate or pilot In electrical operation the contacts in the thermostat are op...

Страница 12: ...e and ignite the burner flame CAUSING A FIRE OR AN EXPLOSION FOR YOUR SAFETY it is recommended that all LP Gas appliances which are vented to the outside shut off when refueling C ICE MAKING Ice cubes...

Страница 13: ...Check burner flame for proper appearance The flame should be light blue with no yellow at the tip See FIG 15 D CHECK GAS PRESSURE The LP gas pressure should be checked and readjusted if necessary Thec...

Страница 14: ...t clogged Remove the burner jet Soak the jet in wood alcohol and blow it out with compressed air Do not use a wire or pin to clean the burner jet B Refrigerator is not level C Flame has gone out Remed...

Отзывы: