Dometic Harrier Lite HL36H401RI Скачать руководство пользователя страница 1

Harrier Lite

HL36H401RI, HL36H401RIY

Roof air conditioner

Operating manual

EN

CLIMATE CONTROL

HARRIER

Harrier-Lite--O.book  Seite 1  Mittwoch, 13. März 2019  9:52 21

More information https://www.caravansplus.com.au

Содержание Harrier Lite HL36H401RI

Страница 1: ...Harrier Lite HL36H401RI HL36H401RIY Roof air conditioner Operating manual EN CLIMATE CONTROL HARRIER More information https www caravansplus com au ...

Страница 2: ...More information https www caravansplus com au ...

Страница 3: ...ls 4 2 Safety instructions 4 2 1 General safety 5 2 2 Operating the device safely 6 3 Target group for this manual 6 4 Intended use 7 5 Technical description 7 5 1 Control panel 8 5 2 Remote control 9 5 3 Air conditioning modes 11 5 4 Additional functions 12 6 Before initial use 12 7 Operating the roof air conditioner 13 7 1 Basic notes on operation 13 7 2 Using the remote control 14 7 3 Hints for...

Страница 4: ...e to the product resulting from mechanical influences and incorrect connection voltage Alterations to the product without express permission from the manufacturer Use for purposes other than those described in the operating manual WARNING Safety instruction Indicates a hazardous situation that if not avoided could result in death or serious injury CAUTION Safety instruction Indicates a hazardous s...

Страница 5: ...or lack of experience and knowledge if they are under supervision or have been given instruction concerning use of the appliance in a safe way and under stand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be performed by children without supervision Only use the device as intended Do not make any alterations or conversions to the device Ins...

Страница 6: ...ditioner is mounted Please ask your vehicle manufacturer if a technical inspection is requiredafterfittinganairconditionerandwhethertheheightentered in your vehicle documents needs to be altered If faults occur in the roof air conditioner s refrigerant circuit the roof air conditioner must be checked by a specialist company and properly repaired The refrigerant must never be released into the air ...

Страница 7: ...to strong vibrations The function of the roof air conditioner is guaranteed for temperatures between 2 C and 52 C 5 Technical description The roof air conditioner supplies the interior with cool or warm air which is without dust and dirt and can be dehumidified The roof air conditioner is operated with the remote control or via the control panel on the air conditioner I NOTE The roof air condition...

Страница 8: ...AU a Technical description Harrier Lite 8 5 1 Control panel The control panel 1 is at the air outlet unit of the roof air conditioner 1 1 AUTO 2 More information https www caravansplus com au ...

Страница 9: ...s on page 12 Indicates the timer is set Displays the set temperature and indicates fan level when fan is adjusted Enables disables automatic mode chapter Air conditioning modes on page 11 Enables disables cooling mode chapter Air conditioning modes on page 11 Enables disables heating mode chapter Air conditioning modes on page 11 Adjusts the fan speed between Low Med High or Auto showing as 1 2 3 ...

Страница 10: ...ollowing Selected room temperature target value in C or F Air conditioning mode Fan level Symbols for active additional functions Adjusts the fan speed between Low Med or High showing as 1 2 3 or AA on the air outlet unit display for a short time when changed Switches ON or OFF the ambient lights in the air outlet unit C F ON OFF h 1 3 More information https www caravansplus com au ...

Страница 11: ...on page 11 Activates the sleep function chapter Additional functions on page 12 Sets the timer Air conditioning mode Display message Explanation Automatic on display on remote control You specify the temperature and the air conditioner brings the interior to this temperature by heating or cooling and by controlling the necessary fan speed Cooling You specify the temperature and fan settings and th...

Страница 12: ...rate at maximum capacity Ventilation The fan operates to circulate air without heating or cooling Dehumidification Dehumidification removes moisture from the air with out heating or cooling the inside The fan speed is Low Additional function Display message Explanation Timer The air conditioner is switched on in the specified number of hours The air conditioner is switched off in the specified num...

Страница 13: ...and from stand by mode switch the ambient lights on and off make the settings select additional functions You can use the remote control to switch the roof air conditioner to and from stand by mode switch the ambient lights on and off make the settings select additional functions Operating mode Features Off The roof air conditioner is switched off The remote control is inactive Stand by The roof a...

Страница 14: ...nditioner The roof air conditioner confirms the receipt of data with a high note Switching only the remote control to or from stand by In stand by mode the remote control display is inactive If the remote control is not pointing to the IR receiver on the control panel you can activate the remote control or switch it to stand by independently from the roof air conditioner Press the button AUTO 1 4 ...

Страница 15: ...ts 7 4 Switching the roof air conditioner on and to stand by I Press the button The roof air conditioner is switched on Press the button again to switch to stand by 7 5 Selecting the air conditioning mode Select the desired air conditioning mode using the MODE button see chapter Air conditioning modes on page 11 The roof air conditioner confirms the receipt of the values with a high note The roof ...

Страница 16: ... the roof air conditioner Heating Mode In the Automatic and Heating modes you can specify a temperature between 16 C and 30 C via the remote control Use the or button to select the desired temperature The roof air conditioner confirms the receipt of the values with a high note The temperature is set on the roof air conditioner Display message Explanation 1 2 3 Fan icon will show plus the number 1 ...

Страница 17: ...ber of hours until the air conditioner will be switched to stand by up to 24 hours I Before programming the timer select the air conditioning mode and all required values e g temperature Setting the switch on and the switch off time I Press the button once The ON symbol flashes on the display of the remote control Use the or button to set the number of hours until the air conditioner will be switc...

Страница 18: ...ner to Stand by Cancelling timer settings If you have set the timer you can cancel these settings as follows Press the button once The timer symbol disappears The setting has been cancelled 7 10 Activating the sleep function I When the sleep function is activated the compressor speed and the fan speed is limited to a lower level to reduce the noise levels for easier sleeping Set the required tempe...

Страница 19: ...remote control I Gently push down the lid of the battery compartment and slide it open in the direction of the arrow Insert the new batteries 2x type AAA in the remote control as indicated in the battery compartment Close the cover of the battery compartment B Protect the environment Do not dispose of batteries with general household waste Return any used batteries to your retailer or take them to...

Страница 20: ...ioner Do not use sharp or hard objects or cleaning agents for cleaning as these may damage the roof air conditioner To clean the roof air conditioner use water with a gentle cleaning agent Never use petrol diesel or solvents NOTICE Beware of damage The air outlet unit display screen 1 is acrylic and can be damaged by some common household chemicals Only use a mild solution of warm soapy water to c...

Страница 21: ...onditioner WARNING Any other maintenance work to that which is described here may only be carried out by qualified personnel who are familiar with the risks involved when handling refrigerant and air conditioning systems as well as the relevant regulations Interval Inspection maintenance Regularly Check the condensation water drainage Check whether the condensation water drainage channels 1 at the...

Страница 22: ...ers back in Once per year Check the profile seals Check the seal between the roof air conditioner and the roof of the vehicle for cracks and other damage Once per year Have the heat exchanger serviced Have the heat exchanger of the roof air conditioner serviced by specialist workshop Once per year Check the fastening bolt tightness Check the fastening bolts are tightened to the correct torque and ...

Страница 23: ... 16 C The roof air conditioner is designed for cooling only at ambient temperatures above 16 C One of the temperature sensors is defective Contactanauthorised service agent or Dometic The evaporator fan is damaged The condenser fan is damaged Not heating well The roof air conditioner is not set to heating Set the roof air conditioner to heating The ambient temperature is below 2 C The roof air con...

Страница 24: ... or Dometic The voltage converter is defective One of the temperature sensors is defective The electrical fuse of the power supply is too low Check the electrical fuse of the power supply Roof air conditionerdoes not switch off One of the temperature sensors is defective Contactanauthorised service agent or Dometic The electrical fuse of the power supply is too low Check the electrical fuse of the...

Страница 25: ...act the manufacturer provides a series of indications here below that should be taken into account by all those who for what ever reason interact with the appliance during its working life All packing components must be disposed of preferably recycled in compliance with statutory legislation in the country in which disposal takes place All product components must be disposed of preferably recycled...

Страница 26: ...egulations Dispose of the product at an official waste disposal facility in accordance with the applicable recycling or disposal guidelines B Protect the environment Do not dispose of any batteries with general household waste Return defective or used batteries to your retailer or dispose of them at collection points Any person who handles or works on equipment containing refrigerant in Australia ...

Страница 27: ...to 240 Vw 50 Hz Power consumption in cooling mode 7 4 A Power consumption in heating mode 4 9 A Required fuse 10 A Operating temperature range 2 C to 52 C Refrigerant R 410A Refrigerant quantity 0 650 kg CO2 equivalent 1 566 t Global warming potential GWP 2088 Protection class outdoor unit IPX4 Suggested max vehicle length with insulated walls 6 m Dimensions L x W x H height above vehicle roof 997...

Страница 28: ...UR LOCAL DEALER dometic com dealer YOUR LOCAL SUPPORT dometic com contact dometic com 1 01 1 0ķ 4 0 1 1 2 ķ 2 1 2 9 0 ĸ DOMETIC GROUP AB 3E 0 1 ĉč ŖĉďĉčČ 4 4445102514 4450018157 54 584 MA03 03 2019 More information https www caravansplus com au ...

Отзывы: