Troubleshooting
25
10
Troubleshooting
Fault
Possible cause
Suggested remedy
Device does not
function, LED does
not glow.
No voltage was
detected in the DC
power outlet.
In most vehicles the ignition must be
turned on before power will be supplied
to the DC power outlet.
No voltage present in
the AC voltage outlet.
Try using another plug outlet.
The device fuse is
defective.
Replace the device fuse, see chapter
“Replacing the AC fuse (CF 35, CF 40,
CF 50)” on page 22.
The integrated power
supply adapter is
defective.
This can only be repaired by an
authorized repair center.
The device does not
cool (plug is inserted,
“POWER” LED is lit).
Defective compressor.
This can only be repaired by an
authorized repair center.
The device does not
cool (plug is inserted,
“POWER” LED flashes
orange, display is
switched off).
Battery monitor is set
too high.
Select a lower battery monitor setting.
Battery voltage is too
low.
Test the battery and charge it as needed.
When operating from
the DC outlet:
The ignition is on
and the device is not
working and the LED
is not lit.
The DC outlet is dirty.
This results in a poor
electrical contact.
If the plug of your cooler becomes very
warm in the DC outlet, either the DC
outlet must be cleaned or the plug has
not been assembled correctly.
The fuse of the DC plug
has blown.
Replace the fuse in the DC plug, see
chapter “Replacing the DC plug fuse” on
page 23.
The vehicle fuse has
blown.
Replace the vehicle’s DC outlet fuse.
Please refer to your vehicle’s operating
manual.