To connect the charging booster proceed as
shown in fig.
Parallel connection of two charging
boosters (fig.
Connection variant, if very high loads occur (e.g.
air conditioning operation) or for large battery
groups to increase the charging power.
!
I
➤
Set the DIP switch position (fig.
1
➤
To connect the charging boosters in parallel
proceed as shown in fig.
Operation
I
Setting the charging program
A
I
➤
Slide the DIP switches (fig.
3
, page 3) to the
position shown in the table below to set the
charging program (OUT) for the respective type
of house battery.
Setting the operating mode
Depending on the operating mode set, the
charging booster is activated via the D+ signal or
the voltage at the starting battery.
➤
Slide the DIP switches (fig.
2
, page 3) to the
position shown in the table below to set the
operating mode (IN).
I
CAUTION! Fire hazard
Ensure that the recommended cable
cross-sections, cable lengths and fuses
are doubled according to the higher
charging currents that may occur.
NOTE
Parallel connection is only permissible if
the devices are of the same type and
capacity.
NOTE
Use a small screwdriver to carefully move
the DIP switches to the required position.
NOTICE! Damage hazard
Only use batteries that are suitable for the
specified charging voltage.
NOTE
• Select the charging program suitable
for the type of house battery used
based on the manufacturer's specifica-
tions, the information in the table
below and the technical data (see
chapter “Technical data” on page 26).
• The specified charging times apply to
an average ambient temperature of
20 °C.
DIP
switch
position
(gray)
Desired charging program
Lead-acid batteries/ AGM 1 batteries
(14.4 V) (fig.
• U1: 14.4 V (0.5 – 4 h)
• U2: 13.5 V
AGM 2 batteries (14.7 V)
(fig.
• U1: 14.7 V (0.5 – 4 h)
• U2: 13.6 V
Lead gel batteries (14.4 V)
(fig.
• U1: 14.4 V (4 – 10 h)
• U2: 13.8 V
LiFePO4 batteries (14.4 V)
(fig.
• U1: 14.4 V (0.3 – 1 h)
• U2: 13.8 V
NOTE
• If the charging booster is activated via
the D+ signal, the starting battery can
be discharged when the ignition is
switched on and the engine is not run-
ning. Use a D+ active simulator if no
D+ signal is available.
• To activate a change of the settings,
disconnect the device temporarily
from the power supply, the starting
battery and the house battery.
B1B2
B1B2
B1B2
B1B2
Содержание BUTTNER MT LB2412-25
Страница 4: ...4 4445103799 3 2 1 100 mm 100 mm 4 5...
Страница 5: ...4445103799 5 2 1 3 90 6 2 3 5 m 4 5 5 m 1 5 m 7...
Страница 7: ...4445103799 7 START Sense START D Kl 15 EBL Start In BORD Sense BORD Temp Sensor D Kl 15 10 A 3 A A 1 c...
Страница 8: ...8 4445103799 B START Sense START D Kl 15 EBL Start In BORD Sense BORD Temp Sensor 3 A 10 A D 2 1 d...
Страница 11: ...4445103799 11 223 270 5 74 g...