EN
Cleaning and maintenance
CFX3
34
8
Cleaning and maintenance
A
➤
Occasionally clean the cooling device interior and exterior with a damp cloth.
➤
Make sure that the air inlet and outlet vents on the device are free of any dust and
dirt, so that heat can be released and the device is not damaged.
9
Troubleshooting
I
NOTICE! Damage hazard
•
Never clean the cooling device under running water or in dish water.
•
Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the cooling device.
NOTE
Customer service: [email protected] or 1-800-544-4881
Fault
Possible cause
Suggested remedy
The device does not
function (DC mode,
ignition on).
No voltage was
detected in the
DC power outlet.
In most vehicles the ignition must be
turned on before power will be supplied
to the DC power outlet.
The DC outlet is dirty.
This results in a poor
electrical contact.
If the plug of the device becomes very
warm in the DC outlet, either the
DC outlet must be cleaned or the plug
has not been assembled correctly.
The fuse of the DC plug
has blown.
Replace the fuse in the DC plug, see
chapter “Replacing the DC plug fuse” on
page 33.
The device DC fuse has
blown.
Replace the device DC fuse, see chapter
“Replacing the DC fuse” on page 33.
The vehicle fuse has
blown.
Replace the vehicle’s DC outlet fuse.
Please refer to your vehicle’s operating
manual.
Содержание 9600024617
Страница 5: ...CFX3 5 1 2 3 1 2 4 3 180 5 ...
Страница 6: ...CFX3 6 1 2 3 1 2 1 2 2 1 3 2 1 180 6 ...
Страница 7: ...CFX3 7 1 1 2 2 7 PLB40 HWK DC 1 1 2 2 3 3 4 4 8 ...
Страница 8: ...CFX3 8 1 1 2 2 3 3 120 V 9 0 DCV 11 8 CLICK 3 3 2 2 1 1 a ...
Страница 9: ...CFX3 9 2 1 1 2 2 1 12 24 V 100 240 V b DCV 11 7 8 C DCV 11 7 8 C A B C c ...
Страница 16: ...CFX3 16 1 2 2 A 5 V q 1 2 3 4 r ...