EN
CF35, CF40, CF 50
Technical data
23
11
Technical data
I
Test/certificates:
The refrigerant circuit contains R134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
Further product information can be accessed via QR code on the energy label in the
figures or via eprel.ec.europa.eu.
NOTE
If the ambient temperature is above +32 °C (+90 °F), the minimum
temperature cannot be attained.
CF35
CF40
Connection voltage:
12/24 V
g
and 100 – 240 V
w
Rated current:
– 12 V
g
:
– 24 V
g
:
– 100 – 240 V
w
:
6.0 A
3.0 A
1.3 to 0.7 A
Cooling capacity:
+20 °C to –18 °C (+68 °F to 0 °F)
Total volume:
35 l
39 l
Climate class:
N, ST, T
Intended ambient temperature use:
+16 °C to +43 °C
Noise emission:
45 dB(A)
Refrigerant quantity:
38 g
41 g
CO
2
equivalent:
0.054 t
0.059 t
Global warming potential (GWP):
1430
Dimensions (W x H x D) in mm:
580 x 385 x 360
580 x 445 x 360
Weight:
15 kg
16 kg
4