8 ENGLISH
5.
Do not short the battery cartridge:
(1)
Do not touch the terminals with any con
-
ductive material.
(2)
Avoid storing battery cartridge in a con
-
tainer with other metal objects such as
nails, coins, etc.
(3)
Do not expose battery cartridge to water
or rain.
A battery short can cause a large current
flow, overheating, possible burns and even a
breakdown.
6.
Do not store the tool and battery cartridge in
locations where the temperature may reach or
exceed 50°C (122°F).
7.
Do not incinerate the battery cartridge even if
it is severely damaged or is completely worn
out. The battery cartridge can explode in a fire.
8.
Be careful not to drop or strike battery.
9.
Do not use a damaged battery.
10.
The contained lithium-ion batteries are subject
to the Dangerous Goods Legislation require
-
ments.
For commercial transports e.g. by third parties,
forwarding agents, special requirement on pack
-
aging and labeling must be observed.
For preparation of the item being shipped, consult
-
ing an expert for hazardous material is required.
Please also observe possibly more detailed
national regulations.
Tape or mask off open contacts and pack up the
battery in such a manner that it cannot move
around in the packaging.
11.
Follow your local regulations relating to dis
-
posal of battery.
SAVE THESE INSTRUCTIONS.
CAUTION: Only use genuine Makita/Dolmar bat
-
teries.
Use of non-genuine Makita/Dolmar batteries, or bat
-
teries that have been altered, may result in the battery
bursting causing fires, personal injury and damage. It
will also void the Makita/Dolmar warranty for the Makita/
Dolmar tool and charger.
Tips for maintaining maximum
battery life
1.
Charge the battery cartridge before completely
discharged.
Always stop tool operation and charge the bat
-
tery cartridge when you notice less tool power.
2.
Never recharge a fully charged battery car
-
tridge.
Overcharging shortens the battery service life.
3.
Charge the battery cartridge with room tem
-
perature at 10°C - 40°C (50°F - 104°F). Let a hot
battery cartridge cool down before charging it.
4.
Charge the battery cartridge if you do not use
it for a long period (more than six months).
FUNCTIONAL
DESCRIPTION
CAUTION:
•
Always be sure that the tool is switched off and
the battery cartridge is removed before adjust
-
ing or checking function on the tool.
Installing or removing battery cartridge
►
Fig.1:
1.
Red indicator
2.
Button
3.
Battery cartridge
CAUTION:
•
Always switch off the tool before installing or
removing of the battery cartridge.
•
Hold the tool and the battery cartridge firmly
when installing or removing battery car
-
tridge.
Failure to hold the tool and the battery
cartridge firmly may cause them to slip off your
hands and result in damage to the tool and
battery cartridge and a personal injury.
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator on the
upper side of the button, it is not locked completely.
CAUTION:
•
Always install the battery cartridge fully until the
red indicator cannot be seen. If not, it may acci
-
dentally fall out of the tool, causing injury to you
or someone around you.
•
Do not install the battery cartridge forcibly. If the
cartridge does not slide in easily, it is not being
inserted correctly.
Battery protection system (Lithium-
ion battery with star marking)
►
Fig.2:
1.
Star marking
Lithium-ion batteries with a star marking are equipped
with a protection system. This system automatically
cuts off power to the tool to extend battery life.
The tool will automatically stop during operation if the
tool and/or battery are placed under one of the following
conditions:
•
Overloaded:
The tool is operated in a manner that causes
it to draw an abnormally high current.
In this situation, release the switch trigger on
the tool and stop the application that caused
the tool to become overloaded. Then pull the
switch trigger again to restart.
If the tool does not start, the battery is over
-
heated. In this situation, let the battery cool
before pulling the switch trigger again.
•
Low battery voltage:
The remaining battery capacity is too low
and the tool will not operate. In this situation,
remove and recharge the battery.
Содержание AH-1853H
Страница 2: ...1 2 3 1 1 2 1 2 3 1 1 2 1 2 3 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 2...
Страница 3: ...1 1 2 3 4 1 1 2 2 3 3 1 2 1 2 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 3...
Страница 4: ...1 1 2 3 1 2 3 4 1 1 1 1 2 3 1 1 2 Fig 17 Fig 18 Fig 19 Fig 20 Fig 21 Fig 22 Fig 23 Fig 24 4...
Страница 5: ...1 Fig 26 Fig 25 5...
Страница 15: ...15 1 1 2 3 2 1 B 3 1 2 0 25 25 50 50 75 75 100...
Страница 16: ...16 4 1 2 3 A B 5 1 1 1 1 10 10 6 1 2 10 7 A B 8 1 2 3 3 4 9 1 10...
Страница 17: ...17 11 12 13 1 2 3 4 14 1 2 3 15 1 2...
Страница 59: ...59...