Opticooler |
Temperature. That Arrives.
Author: M. Thran
Operation Manual Opticooler-TS V1 30_ 2019_05_09.docx09
Page 37 of
44
Version: 1.30
Issued: 09. May 2019
Switch the container off after charging as otherwise there is a risk of damage to the container.
4.6.3. Storage of a Loaded Container
Whenever possible, store the loaded container in a temperature controlled store. The store
temperature shall correspond with the set temperature of the container as close as possible
-
Never expose the container to extreme temperatures beyond the range from -30°C to +50°C
-
Do not cover air inlets and outlets, observe stickers.
-
The container shall be plugged in all the time while storedi
-
Check if the container works properly every two hours, no alerts must be displayed.
Direct sunlight and strong cold winds must be avoided in any case.
Temperatures below -20°C (-4°F) or above +40°C (104°F) have a great negative influence on the
operating time.
!!Caution!!