Opticooler |
Temperature. That Arrives.
Author: M. Thran
Operation Manual Opticooler-TS V1 30_ 2019_05_09.docx09
Page 17 of
44
Version: 1.30
Issued: 09. May 2019
Collective alarm
2.5. Alerts
2.5.1. Types of Alerts
There are three operational alerts:
1.
Alert message:
Temp. deviation
.
The cargo compartment temperature is out of
range. The range is set temperature ± 3°C
2.
Alert message:
Door open
.
The doors are not closed properly.
3.
Alert message:
Batt. nearly empty
.
The battery capacity is below 20%.
Alerts 1 - 3 are indicated by an orange
flashing light and a message on the screen.
There is one technical alert:
4.
This alert indicates a malfunction of the
temperature control system.
This alert is shown in the status bar on the top
of the display as a red flashing line and the
message:
collective alarm
.
The orange flashing light will NOT light up.
If an alert is indicated, the reason for the alert must be rectified immediately. If this is not possible,
the container must be moved as soon as possible into a temperature -controlled facility with the set
transport temperature. Otherwise there is a high risk of temperature deviation with negative impact
on the transported cargo up to a total spoilage of the cargo.
2.5.2. Sequence of Alerts
The alerts are display by priority:
1. “Temp. deviation”
2. “Door open”
3. “Batt. nearly empty”
Alert 4 is displayed independently from all other alerts.
Fig. 2.25 Collective alert
!!Caution!!
Fig. 2.24 Alert 1-3, flash light