DMF series - Torque reaction arms
60353-12/20
16
2.4 Installation
Warning
Protective gloves are recommended while installing torque reaction
arms to avoid pinching and cutting hazards.
2.4.1 Maximal work angle for torque absorption
It is imperative to respect the
angles indicated below in the
working position while installing
the DMF arm.
Angle α
Torque
From
0 to 45°
< 30 Nm
266 (lbf.in)
From
0 to 30°
30 to 100 Nm
266-885 (lbf.in)
From
0 to 20°
100 to 200 Nm
885-1770 (lbf.in)
From
0 to 10°
> 200 Nm
1770 (lbf.in)
Warning
It is not recommended to use horizontally mounted DMF/DMFI arms
(angle α to 0°) longer than 1500 mm.
This causes premature wear of the tubes guide rings.
α