Страница 1: ...USER MANUAL...
Страница 2: ...r reference If there is any difference please take the actual product as the standard The product and batteries must be handled separately from household waste When the product reaches the end of serv...
Страница 3: ...l Parameters 1 Package Contents 2 Pictures 2 Operations 3 1 Security 4 2 Smart 9 3 Intercom 12 4 Message 14 5 Setup 15 Web Settings 18 System Configuration 20 System Diagram 21 Installation 23 Trouble...
Страница 4: ...tates zone and scene setup Smart Support smart home extension by RS485 communication 2 Operating system Linux TECHNICAL PARAMETERS Voltage DC 12V POE Rated power 9W Standby power consumption 1 5W Disp...
Страница 5: ...Quick Start Guide Indoor Monitor MODEL 280M S8 Screw PACKAGE CONTENTS 2 PICTURES Microphone 7 capacitive touch screen Speaker...
Страница 6: ...r DND or undo DND You can use Do Not Disturb service when you don t want to be disturbed by calls The valid time is 8 hours 2 Message Click it to enter the Message interface 3 Network connection When...
Страница 7: ...rface 1 1 1 ON Click Out Home or Sleep icon to activate the alarm sensors The corresponding icon on the main interface will be lit up with a beep and it will stay lit 1 1 2 OFF 1 During the delay time...
Страница 8: ...d 1234 and then you can access the following webpage 1 2 Camera Clicking Camera icon the system will enter into the following interface Click icon or icon button to select the camera you want and then...
Страница 9: ...stop monitoring Fill in with the RTSP format rtsp user password Camera IP IP is the IP address of your IP Camera Then you can monitor IP Camera in Security menu on your indoor monitor 1 3 Zone Remark...
Страница 10: ...pe a dialog box will pop up as below On this interface you can set alarm type as Normal Emergency or 24H 24H and Emergency type are always active NO Type Mode Delay Sensor 1 2 3 4 5 6 7 8 24 Hour 3C 3...
Страница 11: ...ster station if master station is installed in your system You can see the No and sensor type in red color shown at the top of interface Fox example 1 Smoke indicates that smoke sensor in zone 1 is tr...
Страница 12: ...nding time The options of activation time include NONE 30s 40s 60s 100s and 300s You can set the new user password with 1 16 digits the default password is 1234 User password is used for security 1 5...
Страница 13: ...wing interface 2 2 Light Clicking Light icon the system will enter into the following interface Set the light of corresponding room such as Master Sub Living and Dining Rooms see the room setting for...
Страница 14: ...icon the curtain will be paused 2 5 Elevator Clicking Elevator icon the system will enter into the following interface Click or icon to control the up and down of the elevator Click Permit icon to pe...
Страница 15: ...ng interface 3 Intercom 3 1 Call Out Clicking Call Out icon the system will enter the following interface 3 1 1 Call unit resident Input 1 3 digit building No Building 2 digit Unit No Unit 4 digit roo...
Страница 16: ...call management center namely master station the system will call management center 1 to 5 sequentially If the management center cannot be searched or the call failed the system will call next manage...
Страница 17: ...the system will enter the following interface refers to call out record refers to call in record refers to missed call record It can save up to 64 records Click or icon to search for records Select o...
Страница 18: ...page up click icon to page down click icon to delete the record 5 Setup Clicking Setup icon the system will enter into the following interface 5 1 Normal You can select the volume intercom language t...
Страница 19: ...u would like to modify it a keypad will pop up when clicking the setting box twice Enter your new Mask address The Gateway in one system must be on the same segment DNS domain name resolution address...
Страница 20: ...stem password with 1 16 digits the default password is 123456 System password is used for system settings 5 5 Version Click Version icon to enter into the following interface You can look over the rel...
Страница 21: ...ault user name is admin the password is 123456 to enter into the web setting interface 1 Network Click Network icon to enter into the following interface The user can change the IP address of indoor m...
Страница 22: ...The settings are the same with the ones of indoor monitor To connect with SIP phone check Enable and input the number registered in SIP server Timeout Setting of talking time Click Submit icon to sav...
Страница 23: ...ingle mode fiber Four core single mode fiber Fiber Optical Transceiver Fiber Optical Transceiver Fiber Optical Transceiver Fiber Optical Transceiver Management Center Power Management Center PC Fiber...
Страница 24: ...or or other network equipment by network switch When indoor monitor has PoE function the interface can supply power by connecting with PoE network switch If network interface has 12V power supply pin...
Страница 25: ...m Normally closed sensor Normally open sensor Siren equipment Connect with RS485 interface device RS485 interface can output 12V 100mA power supply If RS485 equipment to be connected doesn t require t...
Страница 26: ...Built in box Screws Bracket Suggestion During the installation the camera should be 1450 1550mm above the ground The camera tether for photographing human face should be the top priority Installation...
Страница 27: ...can use it once he she finished the operation Multimedia files cannot be played normally Check whether the system supports the file format Please refer to multimedia setting for details Touchscreen re...
Страница 28: ...the power supply without the manufacturer s approval Do not have the liquids such as water go into the device Clean Device Surface Clean the device surfaces with soft cloth dipped in some water and t...
Страница 29: ...V1 0...