XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
37
TOP
Arming with areas 1, 2, and 3 assigned
BTM
Disarming with areas 1, 2, and 3 assigned
Button Action
This option specifies the Button Action for an individual key fob button. The default
action for the button selected is displayed. Press any select area to display the Button
Action options. To view more options press
CMD
.
ARM (Arm) -
Arms selected areas and force arms bad zones.
DIS (Disarm) -
Disarms selected areas.
TGL (Toggle Arm) -
Toggles arm/disarm for selected areas and force arms bad zones
when arming.
STA (Status) -
Causes the key fob LED to indicate the arm/disarm status of the system.
PN (Panic) -
Triggers a Panic zone type alarm with no restoral.
PN2 (Panic 2) -
Triggers a Panic zone type alarm with no restoral when pressed
simultaneously with any other Panic 2 button. No action occurs when pressed alone.
EM (Emerg) -
Triggers an Emergency zone type alarm with no restoral.
EM2 (Emerg 2) -
Triggers an Emergency zone type alarm with no restoral when pressed
simultaneously with any other Emergency 2 button. No action occurs when pressed
alone.
OUT (Output) -
Causes an output to turn on steady, pulse, momentary, toggle or off.
RST (Sensor Reset) -
Causes the panel to perform a standard Sensor Reset.
UN (Unused) -
The button is not used and performs no action.
Button Press Time
This option specifies the amount of time (SHORT or LONG) the user must press the
button before the key fob sends a message to the wireless receiver. The default press
time displays. Press any select area to set the Button Press Time for Arm, Disarm,
Toggle, Status, Output, and Sensor Reset.
The Button Press Time is not programmable on Panic (PN or PN2), Emergency (EM or
EM2) or Unused (UN) zones. For those zones the button press time is always two (2)
seconds.
SHORT -
Press the button for one-half (1/2) second to send the message to the wireless
receiver.
LONG -
Press the button for two (2) seconds to send the message to the wireless
receiver.
Arm/Disarm Area Selection
For Area systems, enter the areas 1 to 6, to be armed/disarmed by the Key Fob button
being programmed.
This specifies the area to be armed by the Key Fob button being programmed.
For All/Perimeter systems, choose PERIM or ALL.
For Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY.
After selecting the areas, for one-button key fobs the Zone No.: option displays. For
two-button or four-button key fobs, the Key Fob Button Selection option displays to
program additional buttons.
Output Number
You can specify a wireless output to operate when OUT (Output), PN (Panic), PN2
(Panic 2), EM (Emergency), or EM2 (Emergency 2) is selected for a key fob Button
Action. Valid range is 51-54, 61-64, and F1-F20. For an output turned on by a PN, PN2,
EM, or EM2 button action, the output turns off when any area is disarmed.
To enter an output number, press any select area followed by the output number. Press
CMD
.
BUTTON ACTION
YYY: XXXXXXXX
BUTTON ACTION
ARM DIS TGL STA
BUTTON ACTION
PN PN2 EM EM2
BUTTON ACTION
OUT RST UN
BUTTON
PRESS TIME: XXXXX
PRESS TIME:
SHORT LONG
ARM/DIS AREAS
OUTPUT NO: XXX