Digital Monitoring Products
XTLplus International Series Installation and Programming Guide
30
Burglary Output
This output/Favorite turns on any time a burglary zone goes into alarm. The output
turns off when the area in which the alarm occurred disarms and no other burglary
zones are in alarm. Enter 0 (zero) to disable this output.
Arm-Alarm Output
Enter the output/Favorite to turn on steady when any area of the system is armed. If
an alarm occurs causing the keypads to turn Red, this output pulses and continues to
pulse for approximately three (3) minutes after the panel is disarmed. Enter 0 (zero) to
disable.
Heat Saver Temperature
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL or AWAY. When the system is disarmed the thermostats return to their
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
Cool Saver Temperature
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL or AWAY. When the system is disarmed the thermostats return to their
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
Carbon Monoxide Alarm Output
This output turns on any time a Carbon Monoxide Zone (CO) is placed in alarm. The
output is turned off using Sensor Reset option while no additional CO type zones are in
alarm.
Zone Monitor Output
This output turns on momentarily when a zone monitor tone is activated on keypads. If
zone monitoring is turned off, the zone monitor output will not trigger.
BURGLARY OUT: 0
ARM-ALARM OUT: 0
HEAT SAVER
TEMPERATURE: 0
COOL SAVER
TEMPERATURE: 0
OUTPUT OPTIONS
CO ALRM OUT: XXX
OUTPUT OPTIONS
ZN MNTR OUT: XXX