X1 SERIES ELEVATOR CONTROLLER INSTALLATION & PROGRAMMING GUIDE | DIGITAL MONITORING PRODUCTS
6
STEP 3: WIRE FOR FLOOR ACCESS
The X1 Series Elevator Control Module provides 10 Form C (SPDT) 1 Amp relays for controlling access to 10
floors� The three relay terminals are labeled for normally open (NO) and normally closed (NC) operation� The
center terminal is the common� See figures� These allow you to connect the device wiring to the relay for
floor access control�
Warning:
Before wiring for floor access, check with elevator service
company for their desired relay operation for controlling the floors�
1� Wire the number of controlled floors to the elevator control module� To
wire for floor access control, use the 10 terminals on the elevator control
module and label them carefully for the elevator service company�
2� Allow extra wire so that the elevator service company has enough length
to attach to the elevator control center�
3� Ensure the wires are in a logical location for the elevator service technician to find�
PWR
DATA
0 1
2
3
4
5
6
7
8
9
ADDR
6
1
7
8
9
10
2
3
4
5
NC 1 NO
NC 2 NO
NC 3 NO
NC 4 NO
NC 5 NO
NC 6 NO
NC 7 NO
NC 8 NO
NC 9 NO NC 10 NO
NC 1 NO
NC 1 NO
Normally Open
Normally Closed
Top 4-Wire Connector
to X1 Elevator Controller
X1 Elevator Module
NC 1 NO
Normally Open
Common
Normally Closed