background image

X1 SERIES ELEVATOR CONTROLLER INSTALLATION & PROGRAMMING GUIDE  |     DIGITAL MONITORING PRODUCTS 

5

STEP 2:  CONNECT A CARD READER 

The X1 Elevator Controller provides connections for 2 readers� The first reader is designated for the In Reader 

and the second is designated for the Out Reader�  
The X1 Elevator Controller also provides direct 12 VDC output to the reader on the RED terminal connection� 
The elevator service company supplies traveling cable wires for the reader� Document which numbered 

conductors are connecting to which terminals on the elevator controller�

Terminal Name

Wiegand Function

OSDP Function

R1 & R2

12V+

DC +

W1 & W2

Data 1

B (485 +)

G1 & G2

Data 0

A (485 -)

B1 & B2

12V- (ground)

DC -

LC

LED Control

N/A

BC

Wiegand Buzzer Control

N/A

Connect a Wiegand Card Reader

1�  Connect the red wire (12 VDC) to terminal R1�
2�  Connect the white wire (Data One) to W1�
3�  Connect the green wire (Data Zero) to G1, black (ground) to B1�
4�  Connect the orange or brown wire to LC�

Connect an OSDP Card Reader

1�  For data transmission, connect the A wire (485 –) to the G1 terminal and the B wire (485 +) to the W1 

terminal� 

2�  For reader power, connect the red wire (DC + ) to the R1 terminal and the black wire (DC –) to the B1 

terminal�

 Note:

 The wire colors may be different depending on the reader being installed� Refer to the literature 

provided with the reader for wire coding, wire distance, cable type (such as shielded), and other 

specifications� The figure above shows the DMP-recommended wiring�

Optional Second Card Reader

Typical elevator installations do not use a second reader�
For an Out Reader, connect the red, white, green, and black wires to the Reader 2 terminals: R2, W2, G2, and 

B2� Connect the orange/brown wire to LC�
If using only one reader, it must be connected to reader 1�

Red

White
Green

Black

Orange/Brown

(Wiegand LED)

Card Reader

Reader 1 Terminals

R1 W1 G1

B1

LC BC

Содержание X1

Страница 1: ...LT 2463 1 01 21293 2021 X1 SERIES ELEVATOR CONTROLLER INSTALLATION AND PROGRAMMING GUIDE ...

Страница 2: ... and Outputs 7 Onboard Inputs 7 Onboard Outputs 7 Step 5 Determine Communication 8 Ethernet Connection 8 Cellular Connection Optional 8 Wi Fi Connection 8 Step 6 Apply Power 9 Wire the Input Power 9 Wire the Battery 9 Wiring Example 9 Step 7 Manage Connection Settings 10 Configure Wi Fi Settings 10 Configure Network Settings 10 Configure Cell Settings 10 Step 8 Program in Dealer Admin 11 Sign In t...

Страница 3: ...LEV Elevator Controller Elevator Control Module Enclosure This configuration includes all needed parts for up to 10 available floors in one enclosure The X1 ELEV can expand the number of floors through the X1 ELEV EXP and X1 ELEV PCB configurations X1 Elevator Controller Expansion X1 ELEV EXP Elevator Control Module Enclosure This accessory to X1 ELEV Controller is for expanding from 10 to 20 floo...

Страница 4: ... N R and L Terminal C C N R L B D Wi Fi LED E O O 4 Wire Connector Elevator Controller PCB Components Refer to the diagram below throughout the installation Elevator Control Module PCB Components Refer to the diagram below throughout the installation PWR DATA 0 1 2 3 4 5 6 7 8 9 ADDR 6 1 7 8 9 10 2 3 4 5 NC 1 NO NC 2 NO NC 3 NO NC 4 NO NC 5 NO NC 6 NO NC 7 NO NC 8 NO NC 9 NO NC 10 NO Bottom 4 Wire...

Страница 5: ...ller X1 Elevator Expansion Mounting Holes Set the Address The X1 Elevator Control Module has a 1 through 9 addressable rotary dial that is factory defaulted to 1 Additional modules need to be addressed in sequence er 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 First X1 Elevator Module X1 Elevator Controller 12 V Battery 0 1 2 3 4 5 6 7 8 9 Second X1 Elevator Module X1 Elevator Controller X1 Elevator E...

Страница 6: ...ule X1 Elevator Controller 12 V Battery 0 1 2 3 4 5 6 7 8 9 Second X1 Elevator Module 0 1 2 3 4 5 6 7 8 9 Third X1 Elevator Module X1 Elevator Controller X1 Elevator Expansion Optional X1 Elevator Controller PCB Only If not installing additional elevator modules skip to Step 2 Connect a Card Reader Mount the Module The metal enclosure for the X1 Elevator Expansion Module X1 ELEV EXP comes with mou...

Страница 7: ...t the white wire Data One to W1 3 Connect the green wire Data Zero to G1 black ground to B1 4 Connect the orange or brown wire to LC Connect an OSDP Card Reader 1 For data transmission connect the A wire 485 to the G1 terminal and the B wire 485 to the W1 terminal 2 For reader power connect the red wire DC to the R1 terminal and the black wire DC to the B1 terminal Note The wire colors may be diff...

Страница 8: ...ay operation for controlling the floors 1 Wire the number of controlled floors to the elevator control module To wire for floor access control use the 10 terminals on the elevator control module and label them carefully for the elevator service company 2 Allow extra wire so that the elevator service company has enough length to attach to the elevator control center 3 Ensure the wires are in a logi...

Страница 9: ...nnect a motion sensing device or a mechanical switch to provide RX capability to the elevator controller RX can be used to activate the elevator relay When activated the RX activates the elevator relay based on the programmed time This terminal is a Normally Open input Custom Input CI This input triggers a rule programmed in Virtual Keypad This terminal is a Normally Open input Ground G This termi...

Страница 10: ...connects to the right of the cell antenna on the enclosure If the cable has become detached from the X1 simply plug it back onto the Wi Fi module and run the cable around the module X1 Enclosure Wi Fi Antenna Cellular Connection Optional If the network cable or Wi Fi are not connected cell will be the primary communication If the network cable or Wi Fi are connected the cell will be the backup com...

Страница 11: ...PLY POWER Warning Refer to your local state regulations before connecting to building power Wiring methods shall be in accordance with NEC NFPA 72 ANSI and with all Authority Having Jurisdiction Wire the Input Power Connect the transformer wires or external power to terminals 1 and 2 on the X1 PCB Use no more than 70 ft of 16 gauge or 40 ft of 18 gauge wire between the transformer and the X1 PCB W...

Страница 12: ...controller will reset Once the elevator controller has reset it will automatically connect to the customer s network with the updated settings Note If fifteen minutes have passed since power up or the X1 does not broadcast an SSID short the L terminals for 3 seconds and then place the jumper back on one pin of the L terminal This will give an additional fifteen minutes of broadcasting Configure Ne...

Страница 13: ...in as Customer If you are adding an X1 Elevator Controller to an already existing X1 Door Controller site skip to Program the X1 Elevator Controller and Floors Sign In to Dealer Admin Go to the Dealer Admin login page Enter your Email and Password then press Sign In Add a Customer 1 At Customers press the Add icon 2 Enter the customer s name and email 3 Enter the customer s contact information if ...

Страница 14: ...ns as needed Additional Elevator Options Buzzer OSDP allows the reader to beep when a card is read LED OSDP allows the reader LED to turn on and operate the same as a Wiegand reader LED lighting green when the module relay activates If disabled the reader LED is turned off and does not operate in any condition Include in Lockdown allows the elevator to be included when a lockdown is initiated Requ...

Страница 15: ...hird party applications that you want to enable on the elevator controller This allows users to sign in to their services from Virtual Keypad 4 Press Save 5 Back on the System Information page select the number of cameras and storage space you require or choose the number of doorbells that you want to add to the elevator controller Add an App User Adding an app user to an the X1 Elevator Controlle...

Страница 16: ...aler Admin and Virtual Keypad after Dealer Admin programming is completed The elevator control modules each have ten onboard LEDs per floor relay For visual confirmation of the relay operation the LEDs are on when the relay is on and off when the relay is off Log In as a Customer To log in to Virtual Keypad and view the elevator controller like a customer would press Login as Customer This adds yo...

Страница 17: ...l module antenna 2 Unplug the cell module from the cell header 3 Pinch the tab of the standoff to release the cell module from the elevator controller X1 Elevator Controller Initialization Warning This process clears all Dealer Admin programming and defaults the elevator controller back to factory settings 1 Place a jumper over the L header of the elevator controller 2 Within 15 seconds place a ju...

Страница 18: ...o part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in...

Отзывы: