background image

 20 

7400 Series Thinline™ Keypad Installation and Programming Guide     |     Digital Monitoring Products, Inc.

Require Site Code

Press the top row select key or area under 

YES

 to use a site 

code and press 

CMD

 to view the site code entry display. Press 

NO

 to advance to 

NO OF USER CODE DIGITS

. Default is 

NO

.

In addition to user code verification, door access is only 

granted when any one site code programmed at the  

SITE CODE ENTRY

 option matches the site code received in 

the Wiegand string.

Number of User Code Digits

The keypad recognizes user codes from 4-12 digits long. 

Press any top row select key or area to enter a user code digit 

length. This number must match the user code number length 

being programmed in the panel. The device will recommend 

a number of user code digits based on the user code length. 

Default is 

5

.

All bits are read and converted into a decimal number string. 

The number string is left padded with 0 (zero) if needed for 

long user code lengths.

Example:

 

# decoded 

1234567

  10 

digits 

 

 0001234567

  4 

digits 

 4567

REQUIRE SITE
CODE:        

NO

   YES

NO OF USER CODE 
DIGITS:                    

5

Содержание Thinline 7463

Страница 1: ...INSTALLATION AND PROGRAMMING GUIDE 7463 Network Thinline Keypad FRI 2 52 PM 1 2 3 4 5 6 7 8 9 0 CMD A C B D F E G I H J L K V X W S U T P R Q M O N Y Z ENTE R BACK...

Страница 2: ......

Страница 3: ...ypad Address 13 7400 DHCP 13 TABLE OF CONTENTS 7400 IP Address 13 Subnet Mask 14 Gateway Address 14 Panel IP Address 14 Panel IP Port 14 734N Passphrase 15 Default Keypad Message 15 Arm Panic Keys 15...

Страница 4: ...nes Okay 23 Save Programming 23 End User Training 24 Keypad Arming and Disarming 24 Replace the Battery 26 Product Specifications 28 Accessories 28 Certifications 29 Compatibility 29 Built in Proximit...

Страница 5: ...dd IP keypads to XR150 XR550 Series panels The network keypads provide all the same functionality and performance of keypad bus hardwired keypads in situations where running new wire is impossible or...

Страница 6: ...KEYPAD FEATURES Figure 1 7463 Keypad Features FRI 2 52 PM 1 2 3 4 5 6 7 8 9 0 CMD A C B D F E G I H J L K V X W S U T P R Q M O N Y Z ENTE R BACK Armed Power LEDs Proximity Credential Reader and Backl...

Страница 7: ...r on the number pad 3 Identify the Select Key for the character and press that select key on the keypad Press that select key again for the lowercase letter Latin characters only 4 When the desired ch...

Страница 8: ...re reports to the central station in an emergency Enable the panic key function in the keypad user menu Place the supplied icon stickers below the top row select keys The user must press and hold the...

Страница 9: ...re pressed and the speaker has not sounded for 30 seconds the user selected brightness level restores Internal Speaker Tone Adjust the keypad internal speaker tone At SET TONE use the left select key...

Страница 10: ...t a flat screwdriver into one of the slots on the bottom of the keypad and gently lift the screwdriver handle toward you while pulling the halves apart See Figure 2 Repeat with the other slot 2 Using...

Страница 11: ...o connect the keypad to a LAN and power One end of the harness connects to the 6 pin header on the back of the keypad The other end connects to RJ 45 network connector and 12 VDC power See Figure 3 2...

Страница 12: ...ork harness The 7463 keypads communicate AES encrypted TCP with XR Series panels with v201 or higher that have hardwired network installed 3 Power Connection Observing polarity connect the positive re...

Страница 13: ...powered directly over the ethernet connection POE If it is desired to use a POE connection a third party POE splitter can be used to separate 12 VDC from the POE connection to connect to the red and b...

Страница 14: ...t option Refer to the panel programming guide as needed Programming Enter 6653 PROG at the keypad Device Setup Press CMD to advance to DEVICE SETUP and select it Device Number Press CMD to advance to...

Страница 15: ...0 Series Thinline Keypad Installation and Programming Guide 11 Communication Type At COMM TYPE select NET Network Save Press CMD until STOP displays Press a top row select key or area to save programm...

Страница 16: ...P The Keypad Options menu allows you to set the keypad address select Supervised or Unsupervised mode change the default keypad message selectively enable the 2 button Panic keys Bypass REX and set en...

Страница 17: ...he current keypad address from 01 to 08 for XR150 Series panels or 01 to 16 for XR550 Series panels The default address is 01 To change the current address press any select key and enter the new addre...

Страница 18: ...address must match the address programmed in the panel at the Local IP Address option in Network Options The DHCP programming in the panel must be set to NO Panel IP Port Enter the port number that th...

Страница 19: ...at the top of the keypad display Press any select key enter a new message and press CMD Arm Panic Keys Use this option to configure the select keys as two button panic keys To enable or disable a pani...

Страница 20: ...ore the timer expires the keypad automatically selects YES or AWAY Select zero 0 to disable this feature Default is 2 Card Formats Select DMP to allow credentials that use a 26 45 bit data string The...

Страница 21: ...d reads to specific formats only program slots 2 8 See Table 2 Public Card Formats for some publicly available card formats that can be used with the keypad Other private or custom formats may also be...

Страница 22: ...number of bits Default is 26 bits An access card contains data bits for a site code user code and start stop parity bits The starting position location and code length must be determined and programm...

Страница 23: ...string Press select area 4 to clear the site code length and enter a number between 1 24 Press CMD to save Default is 8 User Code Position and Length Define the user code start bit position and length...

Страница 24: ...the site code received in the Wiegand string Number of User Code Digits The keypad recognizes user codes from 4 12 digits long Press any top row select key or area to enter a user code digit length T...

Страница 25: ...e duration but turns off at the end of the door strike timer Press the second select key or area to choose SITE Accept Site Code Door access is granted when the Wiegand site code string received match...

Страница 26: ...22 7400 Series Thinline Keypad Installation and Programming Guide Digital Monitoring Products Inc Save Programming Select STOP to save and exit programming KPD KPD OPT DIAG STOP...

Страница 27: ...backlighting then changes to green The keypad alternates between these two states for approximately two minutes Press CMD at any time to begin testing individual keys Test Individual Keys The keypad...

Страница 28: ...option 3 The keypad displays ENTER CODE The user presents their card to the reader Once validated by the system all areas assigned to that code arm or disarm automatically See Figure 7 Figure 7 Area...

Страница 29: ...y the system the selected areas arm or disarm automatically Home Away System Arming and Disarming Present your card to the reader If the system is armed once the card is validated all areas are disarm...

Страница 30: ...ps See Figure 9 3 Lean the keypad backwards and lift out from the bottom PCB snaps Replace Battery 1 Disconnect the battery lead connector from the keypad battery header 2 Remove the standby battery f...

Страница 31: ...Keypad PCB 1 Set the PCB into the bottom snaps with the elastomer keyboard already in place See Figure 9 2 Line up the PCB alignment post with the hole in the PCB 3 Press the PCB into the top PCB sna...

Страница 32: ...e 12 VDC Current Draw Standby 100 mA Alarm 100 mA Max Battery Charging 285 mA Dimensions 7 W x 5 25 H x 0 5 D 17 78 W x 13 34 H x 1 27 D cm Backup Battery 800 mAh 4 hours standby power ACCESSORIES 300...

Страница 33: ...Installation and Programming Guide 29 CERTIFICATIONS FCC Part 15 RFID Reader FCC ID CCKPC0216 Industry Canada ID 5251A PC0216 Underwriters Laboratory UL Listed ANSI UL 1610 Central Station Burglar Ala...

Страница 34: ...of publicly supported card formats see Table 2 Table 2 Public Card Formats CARD FORMAT WIEGAND CODE LENGTH SITE CODE POSITION SITE CODE LENGTH USER CODE POSITION USER CODE LENGTH USER CODE DIGITS H10...

Страница 35: ...application before installation DMP does not guarantee compatibility with credentials not purchased from DMP See Table 3 for a list of some compatible credentials 125 kHZ PROXIMITY CREDENTIALS PSC 1...

Страница 36: ...he user s authority to operate the equipment Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are...

Страница 37: ...any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence...

Страница 38: ...0 Series Thinline Keypad Installation and Programming Guide Digital Monitoring Products Inc Information furnished is believed to be accurate and reliable This information is subject to change without...

Страница 39: ......

Страница 40: ...LT 2006 1 01 20113 2020 Digital Monitoring Products Inc...