8
7400 Series Thinline™ Keypad Installation and Programming Guide | Digital Monitoring Products, Inc.
Network Connection
Connect an IP network cable from the
LAN/WAN connection to the female
RJ-45 connector on the 300-7400-6
network harness.
The 7463 keypads communicate
AES encrypted TCP with XR Series
panels with v201 or higher that have
hardwired network installed.
3
Power Connection
Observing polarity, connect the
positive (red) and negative (black)
wires of the 300-7400-6 network
harness to the corresponding positive
and negative wires of a 12 VDC power
supply, the 371-500L. See Figure 4.
4
Red
Black
Positive
Negative
Figure 4: Power Supply to Harness