738I ITI™ Installation and Programming Guide | Digital Monitoring Products, Inc.
PROGRAM THE 738I ITI™
1.
Connect the Model 330 Programming Cable from the PROG header to any DMP
thinline, wireless, or graphic touchscreen keypad set to address 1. Refer to the
specific keypad installation sheet for information on changing the keypad address.
2. Place the jumper across the PROGRAM header. The 738I immediately enters
programming mode.
3. Press the
CMD
key to continue.
Note:
While in programming mode, all 738I communication to the panel stops.
Initialization
Press the Select key under
YES
to reset all programming
options to the factory default. Press the Select key under
NO
to maintain all programming options at their current settings.
Panel Bus Type
Press the Select key under
KYPD
when connecting the 738I
to the panel keypad bus. Press the Select key under
LX
when
connecting the 738I to the panel LX-Bus. Press the
CMD
key to
accept the selection. An asterisk appears to the left of the bus
type selected.
INIT ALL? NO YES
BUS: *KYPD LX