1135 INTERNATIONAL WIRELESS SIREN

Installation Guide

DESCRIPTION

The 1135INT Series Wireless Siren 

provides up to 110 decibels of 

annunciation. It includes a wall 

tamper, a cover tamper, and a 

Survey LED. 

Multiple sirens can be activated 

simultaneously by the panel using 

the Trip with Panel Bell option. This 

option allows the siren to follow the 

panel bell output including the bell 

cutoff time. 

In addition to these features, 

the 1135INT Wireless Siren 

communicates with the panel using 

128‑bit AES encryption.

Compatibility

• 

1100XINT Wireless Receiver 

Version 700 and Higher

• 

1100DINT Wireless Receiver 

Version 700 and Higher

• 

XT30INT/XT50INT Series Panels 

Version 693 and higher

• 

XTLplusINT/XTLtouchINT Series 

Panels Version 693 and Higher

• 

XR150INT/XR550INT Series 

Panels Version 693 and Higher

What is Included?

• 

One 1135INT Series Wireless Siren

• 

Two 3.0 V Lithium CR123 

Batteries

• 

Hardware Pack

1

PROGRAM THE PANEL

To program the 1135INT Series into the panel, select one of the 

following methods: Choose Method 1 to make the siren a non‑

standard output that follows the panel bell or Method 2 to make 

the siren a standard output.

A house code must be programmed in the panel’s 

SYSTEM 

OPTIONS

 before programming wireless devices. Range is 1 ‑ 50.

To enter panel programming, reset the panel and enter the 

programming menu code at a keypad: For international XR Series 

enter 

6653

 (PROG). For international XT and XTL Series, enter 

665

 

(PRO). 

After completing each of the following steps, press 

CMD

 to 

advance to the next prompt. After you finish programming, go to 

STOP

 and press 

CMD

 to save and exit the Programmer menu. For 

more information, refer to the appropriat

panel programming 

guide

PANEL MODEL

VALID OUTPUT NUMBERS

XR Series

450‑474 (slow) or 480‑499 (fast)

XT Series

31‑34 (slow) or 41‑44 (fast)

XTL Series

51‑54 (slow) or 61‑64 (fast)

Table 1: Valid Output Numbers by Panel Model

Method 1: Non-Standard Output (Follow Panel)

1.  Go to 

OUTPUT INFO

 (XR Series) or 

OUTPUT SETUP

 

(XT and XTL Series). 

2.  At 

OUTPUT NO

, enter the output number. Refer to 

Table 1

.

3.  At 

OUTPUT NAME

, enter a descriptive name for the siren.

4.  At 

SERIAL#

, enter the 8‑digit device serial number.

5.  At 

SUPRVSN TIME

, enter the supervision time in minutes. 

6.  Ensure 

TRIP WITH PANEL BELL

 is set to 

YES

 (default).

7.  Go to 

BELL OPTIONS

 and set the 

BELL CUTOFF

. Range is 

1 ‑ 15 minutes.

Method 2: Standard Output (Standalone)

1.  Go to 

OUTPUT INFO

 (XR Series) or 

OUTPUT SETUP

 

(XT and XTL Series). 

2.  At 

OUTPUT NO

, enter the output number. Refer to 

Table 1

.

3.  At 

OUTPUT NAME

, enter a descriptive name for the siren.

4.  At 

SERIAL#

, enter the 8‑digit device serial number.

5.  At 

SUPRVSN TIME

, enter the supervision time in minutes. 

6.  At 

TRIP WITH PANEL BELL

, select 

NO

.