1135 INTERNATIONAL WIRELESS SIREN
Installation Guide
DESCRIPTION
The 1135INT Series Wireless Siren
provides up to 110 decibels of
annunciation. It includes a wall
tamper, a cover tamper, and a
Survey LED.
Multiple sirens can be activated
simultaneously by the panel using
the Trip with Panel Bell option. This
option allows the siren to follow the
panel bell output including the bell
cutoff time.
In addition to these features,
the 1135INT Wireless Siren
communicates with the panel using
128‑bit AES encryption.
Compatibility
•
1100XINT Wireless Receiver
Version 700 and Higher
•
1100DINT Wireless Receiver
Version 700 and Higher
•
XT30INT/XT50INT Series Panels
Version 693 and higher
•
XTLplusINT/XTLtouchINT Series
Panels Version 693 and Higher
•
XR150INT/XR550INT Series
Panels Version 693 and Higher
What is Included?
•
One 1135INT Series Wireless Siren
•
Two 3.0 V Lithium CR123
Batteries
•
Hardware Pack
1
PROGRAM THE PANEL
To program the 1135INT Series into the panel, select one of the
following methods: Choose Method 1 to make the siren a non‑
standard output that follows the panel bell or Method 2 to make
the siren a standard output.
A house code must be programmed in the panel’s
SYSTEM
OPTIONS
before programming wireless devices. Range is 1 ‑ 50.
To enter panel programming, reset the panel and enter the
programming menu code at a keypad: For international XR Series
enter
6653
(PROG). For international XT and XTL Series, enter
665
(PRO).
After completing each of the following steps, press
CMD
to
advance to the next prompt. After you finish programming, go to
STOP
and press
CMD
to save and exit the Programmer menu. For
more information, refer to the appropriate
.
PANEL MODEL
VALID OUTPUT NUMBERS
XR Series
450‑474 (slow) or 480‑499 (fast)
XT Series
31‑34 (slow) or 41‑44 (fast)
XTL Series
51‑54 (slow) or 61‑64 (fast)
Table 1: Valid Output Numbers by Panel Model
Method 1: Non-Standard Output (Follow Panel)
1. Go to
OUTPUT INFO
(XR Series) or
OUTPUT SETUP
(XT and XTL Series).
2. At
OUTPUT NO
, enter the output number. Refer to
3. At
OUTPUT NAME
, enter a descriptive name for the siren.
4. At
SERIAL#
, enter the 8‑digit device serial number.
5. At
SUPRVSN TIME
, enter the supervision time in minutes.
6. Ensure
TRIP WITH PANEL BELL
is set to
YES
(default).
7. Go to
BELL OPTIONS
and set the
BELL CUTOFF
. Range is
1 ‑ 15 minutes.
Method 2: Standard Output (Standalone)
1. Go to
OUTPUT INFO
(XR Series) or
OUTPUT SETUP
(XT and XTL Series).
2. At
OUTPUT NO
, enter the output number. Refer to
3. At
OUTPUT NAME
, enter a descriptive name for the siren.
4. At
SERIAL#
, enter the 8‑digit device serial number.
5. At
SUPRVSN TIME
, enter the supervision time in minutes.
6. At
TRIP WITH PANEL BELL
, select
NO
.