background image

DMEGC Photovoltaic Modules Installation Manual

- 1 -

1. General Information

Thanks for choosing DMEGC Solar PV modules.

This guide contains information regarding the installation and safe handling of DMEGC photovoltaic

module (hereafter is referred to as “module”)

All instructions should be read and understood before attempting to install. If there are any questions,

please contact our sales department for further explanation. The installer should conform to all the safety
precautions in the guide when installing the module. Local codes should also be followed in such
installation.

Before installing a solar photovoltaic system, the installer should become familiar with the mechanical

and electrical requirement for such a system. Keep this guide in a safe place for further reference (care and
maintenance) and in case of sale or disposal of the module.

2.

Safety precautions

DMEGC solar Modules are designed to meet the requirements of IEC 61215 and IEC 61730, applocation
class A, Modules rated for use in this applications class may be used in system operating at greater than
50V DC or 240W, where general contact access is anticlpated Modules qualified for safety through IEC
61730-1 and IEC 61730-2 and within this application class are considered to meet the requirements for
safety class II equipment.

2.1 General Safety

Installing solar photovoltaic systems requires specialized skills and knowledge.

Installation must only be performed by authorized and trained personnel. Installers must assume all
risks of injury that might occur during installation, including, but not limited to, the risk of electric
shock.

One single module may generate more than 30V DC when exposed to direct sunlight. Contact with a
DC voltage is potentially hazardous and should be always avoid.

PV modules are recommended to be installed at altitudes of less than 2000m.

Modules can be ground mounted, mounted on rooftops. The proper design of support structures lies
within the responsibility of the system designers and installers.

When installing the system, abide to all local, regional and national statutory regulations. Obtain a

Содержание DM M2-60BW Series

Страница 1: ...agnetics Co Ltd DMEGC Solar Energy Hengdian Industrial Area Dongyang City Zhejiang Province China Tel 86 579 86554950 Fax 86 579 86554845 Email solar dmegc com cn DMEGC Photovoltaic Modules Installati...

Страница 2: ...RE SAFETY 4 3 PRODUCT IDENTIFICATION 4 4 MECHANICAL INSTALLATION 5 4 1 SELECTING THE LOCATION 5 4 2 TILT ANGLE SELECTION 5 4 3 CONVENTIONAL REQUIREMENTS 6 4 4 INSTALLATION METHODS 7 4 5 ATTACHMENT GUI...

Страница 3: ...30 applocation class A Modules rated for use in this applications class may be used in system operating at greater than 50V DC or 240W where general contact access is anticlpated Modules qualified for...

Страница 4: ...they are ready to be installed Store pallets in a ventilated rain proof and dry location until the Modules are ready to be unpacked During the transportation do not to apply direct pressure on the bac...

Страница 5: ...module unnecessarily during installation The glass surface and the frame may be hot there is a risk of burns and electric shock Do not work in the rain snow or in windy conditions Avoid exposing cabl...

Страница 6: ...heet and the mounting surface Roof construction and installation may affect the fire safety of the building Improper installation may create hazards in the event of a fire Use appropriate components s...

Страница 7: ...he coastline Confirm with DMEGC install after obtaining approval Modules must be installed or operated in areas where salt hail snow sand dust air pollution chemically active acid rain soot etc are ex...

Страница 8: ...is 2900 PSI 20 Mpa in order to avoid potential damages to module frames Follow the instruction of the clamping system supplier Provide adequate ventilation under the modules in conformity to your loc...

Страница 9: ...e suggest stainless steel M8 bolts should be around 15 20 N m the mounting details are shown in the following figures 4 4 2 Mounting with Clamps When choosing this type of clamp mounting method use at...

Страница 10: ...eet a maximum positive pressure of 1600Pa and negative pressure of 1600 Pa this design load was then tested with a safety factor of 1 5 times The high loading capacity applies to severe environment li...

Страница 11: ...DMEGC Photovoltaic Modules Installation Manual 9 4 5 1Framed module bolt and clamp installation...

Страница 12: ...DMEGC Photovoltaic Modules Installation Manual 10 4 5 2 Frameless clamp installation...

Страница 13: ...mum number of series connected modules depends on system design the type of inverter used and environmental conditions Based on the maximum series fuse rating of module and local electrical installati...

Страница 14: ...l utility are generally required Especially for larger installations DMEGC recommends lightning protection following the local requirements and regulations 6 Grounding For grounding and bonding requir...

Страница 15: ...381 are used with metal framed photovoltaic solar panels and related products that require grounding for safety reasons 3 Addition Third party Grounding Devices DMEGC PV Modules can be grounded using...

Страница 16: ...ater and a soft sponge or cloth for cleaning A mild nonabrasive cleaning agent can be used to remove stubborn dirt In order to reduce the potential for electrical and thermal shock DMEGC recommends cl...

Страница 17: ...out of or in any way connected with such installation operation use or maintenance No responsibility is assumed by DMEGC for any infringement of patents or other rights of third parties which may res...

Страница 18: ...xxxB6 60NT DMGxxxB6 60NT DMxxxM2 B60NT DMxxxM2 B60NT Group 5 72 156 75 cells modules with aluminium frame xxx 355 370 in increment of 5 DMGxxxM6 72BT DMGxxxM6 72BW DMGxxxM6 72ST DMGxxxM6 72SW DMGxxxM6...

Страница 19: ...DMxxxM2 B72HBT DMxxxM2 B72HSW DMxxxM2 B72HBW Group 11 120 166 cells modules with aluminium frame xxx 355 375 in increment of 5 DMxxxM6 G60HST DMGxxxM6 G60HBT DMxxxM6 G60HSW DMxxxM6 G60HBW Group 12 120...

Отзывы: