1100R SERIES
WIRELESS REPEATER
Installation Guide
DESCRIPTION
Figure 1: 1100R Wireless Repeater
WALL
TAMPER
ENABLE
DISABLE
BAT
The 1100R Series Wireless Repeaters
provide an increased communication
range by forwarding messages
from the transmitter to the wireless
receiver. The 1100RE features
128‑bit AES encryption.
Up to eight repeaters can be installed
on a wireless system. The repeater
is powered from a 12 VDC power
supply and includes a 24‑hour battery
backup.
Compatibility
•
All DMP 1100 Series Wireless
Receivers using Version 106 or
higher software.
•
All DMP panels with a built‑in
wireless receiver.
•
Encryption requires panel
version 183 or higher and wireless
receiver version 300 or higher.
•
The 1100R is not compatible with
the 1100T Wireless Translator
What is Included?
•
1100R Repeater
•
800 mAh Lithium Polymer
Rechargeable Battery
•
376L Plug‑In DC Power Supply
•
Hardware Pack
1
PROGRAM THE PANEL
Refer to the panel programming guide as needed. See links in
Additional Information
.
After completing each of the following steps, press
CMD
to
advance to the next option.
1. Reset the panel. At a keypad, enter
6653
(PROG) to access
the PROGRAMMER menu.
2. In
ZONE INFORMATION
, enter the wireless zone number
from the table below. If using multiple repeaters, they must
be programmed as sequential zone numbers.
3. At
*UNUSED*
, enter the name of the repeater or repeater’s
location for easy identification later.
4. Select
AUX 1
(auxiliary 1) as the
ZONE TYPE
.
5. At
WIRELESS?
select
YES
.
6. At
SERIAL NO
, enter the repeater’s eight‑digit serial number.
7. At
SUPRVSN TIME
, enter a supervision time. Default is
240
.
8. At the
NEXT ZONE
prompt, select
NO
for more
programming options.
9. Program
ARMED OPEN
and
DISARMED OPEN
as
TROUBLE
so that a power trouble sends a trouble alert.
10. Program
ARMED SHORT
and
DISARMED SHORT
as
ALARM
so that a tamper sends an alarm alert.
11. Press
CMD
until
STOP
displays. Press a top row select key or
area to save programming.
2
The 1100R is equipped with a case and wall tamper. When the
housing cover is removed, the case tamper activates and the 1100R
sends a tamper trouble to the panel.
A two‑position header is provided to enable or disable the wall
tamper. To enable the tamper, place the jumper on the top two pins.
To disable the tamper, place the jumper on the bottom two pins.
ENABLE OR DISABLE THE TAMPER
DMP Panel
Available
Zones
Zone Ranges
XTLplus and
XTLtouch
99
1 ‑ 99
XT50 with built‑in
receiver
48
11 ‑ 14, 21 ‑ 24, 31 ‑ 34, 41 ‑ 44, 51 ‑ 54,
61 ‑ 64, 71 ‑ 74, 81 ‑ 84, 80, 85 ‑ 99
XT30 and XT50
(1100D Series)
32
11 ‑ 14, 21 ‑ 24, 31 ‑ 34, 41 ‑ 44, 51 ‑
54, 61 ‑ 64, 71 ‑ 74, 81 ‑ 84
XR150 (1100X Series)
100
500 ‑ 599
XR550 (1100X Series)
500
500 ‑ 999