1100R SERIES 

WIRELESS REPEATER

Installation Guide

DESCRIPTION

Figure 1: 1100R Wireless Repeater

WALL

TAMPER

ENABLE

DISABLE

BAT

The 1100R Series Wireless Repeaters 

provide an increased communication 

range by forwarding messages 

from the transmitter to the wireless 

receiver. The 1100RE features 

128‑bit AES encryption. 

Up to eight repeaters can be installed 

on a wireless system. The repeater 

is powered from a 12 VDC power 

supply and includes a 24‑hour battery 

backup. 

Compatibility

• 

All DMP 1100 Series Wireless 

Receivers using Version 106 or 

higher software.

• 

All DMP panels with a built‑in 

wireless receiver.

• 

Encryption requires panel 

version 183 or higher and wireless 

receiver version 300 or higher.

• 

The 1100R is not compatible with 

the 1100T Wireless Translator

What is Included?

• 

1100R Repeater

• 

800 mAh Lithium Polymer 

Rechargeable Battery

• 

376L Plug‑In DC Power Supply

• 

Hardware Pack

1

PROGRAM THE PANEL

Refer to the panel programming guide as needed. See links in 

Additional Information

.

After completing each of the following steps, press 

CMD

 to 

advance to the next option.

1.  Reset the panel. At a keypad, enter 

6653

 (PROG) to access 

the PROGRAMMER menu. 

2.  In 

ZONE INFORMATION

, enter the wireless zone number 

from the table below. If using multiple repeaters, they must 

be programmed as sequential zone numbers.

3.  At 

*UNUSED*

, enter the name of the repeater or repeater’s 

location for easy identification later.

4.  Select 

AUX 1 

(auxiliary 1) as the 

ZONE TYPE

.  

5.  At 

WIRELESS?

 select 

YES

6.  At 

SERIAL NO

, enter the repeater’s eight‑digit serial number. 

7.  At 

SUPRVSN TIME

, enter a supervision time. Default is 

240

.

8.  At the 

NEXT ZONE

 prompt, select 

NO

 for more 

programming options. 

9.  Program 

ARMED OPEN

 and 

DISARMED OPEN

 as 

TROUBLE

 

so that a power trouble sends a trouble alert.

10.  Program 

ARMED SHORT

 and 

DISARMED SHORT

 as 

ALARM

 

so that a tamper sends an alarm alert.

11.  Press 

CMD

 until 

STOP

 displays. Press a top row select key or 

area to save programming.

2

The 1100R is equipped with a case and wall tamper. When the 

housing cover is removed, the case tamper activates and the 1100R 

sends a tamper trouble to the panel. 
A two‑position header is provided to enable or disable the wall 

tamper. To enable the tamper, place the jumper on the top two pins. 

To disable the tamper, place the jumper on the bottom two pins.

ENABLE OR DISABLE THE TAMPER

DMP Panel

Available 

Zones

Zone Ranges

XTLplus and 
XTLtouch

99

1 ‑ 99

XT50 with built‑in 
receiver

48

11 ‑ 14, 21 ‑ 24, 31 ‑ 34, 41 ‑ 44, 51 ‑ 54, 
61 ‑ 64, 71 ‑ 74, 81 ‑ 84, 80, 85 ‑ 99

XT30 and XT50 
(1100D Series)

32

11 ‑ 14, 21 ‑ 24, 31 ‑ 34, 41 ‑ 44, 51 ‑ 
54, 61 ‑ 64, 71 ‑ 74, 81 ‑ 84

XR150 (1100X Series)

100

500 ‑ 599

XR550 (1100X Series)

500

500 ‑ 999