QuickStart

FlexxPump 250 / 400 time

5.3 Actions with the activation and programming key

1. 

Turn the activation and programming 

key to the OPEN position and remove it 

from the housing of the FlexxPump  

250 / 400.

2. 

Place the key on the action area on 

the front of the FlexxPump 250 / 400 time. 

3. 

Remove the key from the action 

area as long as the desired menu item is 

displayed in the LCD.

5.4 SET-menu

The SET menu allows you to change the operating mode and the 

cartridge size of the FlexxPump 250 / 400 time. You can switch 

between hour mode -h- and empty time mode Et

5.5 PRO menu

 

Being in operating mode hour mode -h-, you can change the break 

time h as well as the number of cycles c (number of strokes). 

Being in PRO menu the first step is to set the break time h and after-

wards the number of cycles c; direct access to the number of cycles 

c is not possible. 

Running empty time mode Et, you can change the emptying time Et 

in months.

5.6 FIL menu 

This function enables you to prefill connected accessories (tubes, 

distributors,...) with the lubricant contained in the lubricant cartridge, 

especially during the initial start-up. However, the process can also 

be aborted manually at any time.

PIN assignment - time control

PIN

Assignment

Colour

1

+24 V DC

brown

2

unallocated

white

3

ground

blue

4

output signal

black

Type: M12x1 female connector; 4-pin, A-coded

The FlexxPump 250 / 400 time can be switched off completely by 

switching off the supply voltage.

 The output signal at PIN 4 can be tapped for further processing 

(e.g. indicator light or external control). The maximum permissible 

current output must not exceed Imax < 20mA. No inductive load 

(e.g. relay) may be connected! 

5.8 Input and output signals

LCD

Description

Output signal (PIN 4)

OFF

switched off

low, permanent

ON

ready for operation

high, permanent

E1

cartridge empty

0,5Hz square wave signal, permanent

E2

overload

low, permanent

E3

undervoltage

low, permanent

E4

fatal error

low, permanent

 

The FlexxPump 250 / 400 time does not process any control 

signals until all errors have been eliminated.

 

 

Error E2 (overload) must be acknowledged with switching the 

pump off and on after elimination of the cause(s). 

 

 

Error E3 (undervoltage) must be acknowledged with switching 

the pump off and on after elimination of the cause(s). 

 

IMPORTANT: 

There must be at least 60 sec. between switching 

off and on!

6. Maintenance

Notice

It is not possible to refill empty or opened lubricant cartridges.

3

2

1

4

5.7 Input and output signals - time control

-h-  

Operating mode hour mode -h- 

Et  

Operating mode Empty-time 

125/250  

Cartridge size 

If you would like to change the operating mode, move the activation 

and programming key back to the action area. When your desired 

operating mode is displayed on the LCD, remove the activation and 

programming key from the action area. If you would like to change 

the cartridge size, act accordingly.

RUN

RUN-Menü
01...70

During the manually triggered active RUN command („quick 

check“/extra dispense), the LCD displays the approximate 

back pressure in bar. In addition, the green LED lights up.

PRO

PRO-Menü
h1...240

Adjustable setting of break time h

c1...30

Adjustbale setting of number of strokes c

01...36

Adjustabe setting of emptying time Et

FIL

FIL-Menü
01...70

During the manually triggered, active FIL command, the LCD 

displays the approximate back pressure in bar. In addition, 

the green LED lights up.

Clr

If the process is aborted during FIL command Clr appears 

at first.

Additional character on the LCD

1 / 2

During a dispensing process the FlexxPump 250 / 400 time 

indicates from which outlet lubricant is being pumped.

MAX

After each cycle the maximum back pressure is displayed in 

bar.

Rev.: 

SG-20210914