QuickStart
FlexxPump 125 B
Display in LCD
Description
Submenus
INF
INF-menu
b11
Firmware version of the FlexxPump 125 B
h06
Currently set value of break time h
c01
Currently set value of number of strokes c
06
Currently set value of emptying time Et
SET
Set-menu
-h-
Operating mode: hour mode
Et
Operating mode: empty time mode
RUN
RUN-menu
01...35
During the manually triggered active RUN com-
mand („quick check“/extra dispense), the LCD
displays the approximate back pressure in bar. In
addition, the green LED lights up.
PRO
PRO-menu
h1...99
Adjustable setting of break time h
c1...10
Adjustbale setting of number of strokes c
01...24
Adjustabe setting of emptying time Et
FIL
FIL-menu
01...35
During the manually triggered active FIL command,
the LCD displays the approximate back pressure in
bar. In addition, the green LED lights up.
Clr
If the process is aborted during the FIL command,
Clr appears at first.
Additional characters on the LCD
Displayed when the cartridge is empty and the
cartridge and battery need to be replaced.
MAX
After each cycle the maximum back pressure is
displayed in bar.
5.3 Actions with the activation and programming key
1. Remove the activation and pro-
gramming key from the underside of the
FlexxPump 125 B.
2. Place the activation and programming
key on the action area on the front of the
FlexxPump 125 B.
3. Remove the activation and pro-
gramming key from the action area as
long as the desired menu item is displayed
in the LCD
5.4 SET menu
The SET menu allows you to change the operating mode of the
FlexxPump 125 B. You can switch between
hour mode -h-
and
empty time mode Et.
h
set
set
2x
et
2x
Et
SEt-Menü
On
If you would like to change the operating mode, move the activation
and programming key back to the action area.
When your desired operating mode is displayed on the LCD, remove
the activation and programming key from the action area.
5.5 PRO menu
Being in operating mode hour mode -h-, you can change the break
time h as well as the number of cycles c (number of strokes).
Being in PRO menu the first step is to set the break time h and after
-
wards the number of cycles c; direct access to the number of cycles c
is not possible.
Being in empty time mode Et, you can change the emptying time Et
in months.
5.6 FIL menu
This function enables you to prefill connected accessories (tubes,
distributors,...) with the lubricant contained in the lubricant cartridge,
especially during the initial start-up of the FlexxPump 125 B. Howe-
ver, the process can also be aborted manually at any time.
-h-
Operating mode: hour mode -h-
Et
Operating mode: empty time mode Et
6. Maintenance
Notice
A used lubricant cartridge must not be replaced on the FlexxPump
125 B as the integrated stroke counter of the FlexxPump 125 B is
automatically reset by the cartridge sensor after a cartridge has
been removed. Only use full lubricant cartridges.
Notice
The battery of the FlexxPump 125 B must be replaced at the same
time as the lubricant cartridge.