DLG E-BOX-48100R LFP Battery User Manual
16
connection;
2. Turn all battery POWER buttons to “ON”;
3. Single battery: press the SW button of the battery for 1 second.
If the 8 indicator lights of the battery are on for 1 second, the battery
is activated.
Multiple batteries: press SW button of any battery for 1 second.
If 8 indicator lights of all batteries are on for 1 second, all batteries
are activated.
Note: When the battery power is too low to be turned on, charge
the battery by connecting the battery to ESS inverter.
6.4.6 Power-on test
1. Turn on the battery and energy storage inverter or DC power
supply;
2. Check whether the battery is operating normally by referring
to "table 6-3 LED instructions";
1) If the battery is not fully charged and the energy storage
inverter has successfully charged the battery, then the battery enters
the charging state;
2) If the battery is fully charged and the battery does not supply