User manual for meter with U/I input PD96
51
2
after writing to register no 20h the device responds with an
“old” address in the message.
3
after writing to register no 22h the device responds with the new baud rate
4
he value of the
“
mbAc
” parameter is also connected to write to this register, so it is possible to block a writes, but
impossible to unblock writes via RS-485 interface, The unblocking of the writes is possible from menu level only.
5
the pairs of „
X
-
Y
” coordinates may be defined for any free point. The pair is “free” (it means that particular point is
not defined) if „
X
” coordinate of this point is equal 8000h. After writing both X and Y coordinate the point is defined
and used in calculation of result. The coordinates of any point can be changed at any time.
11.2. Transmission errors description
If an error occurs while write or read of single register, then the device sends an error
code according to Modbus RTU specifications (example message no 1).
Error codes:
01h
- illegal function (only functions 03h, 06h and 10h are available),
02h
- illegal register address
03h
- illegal data value
08h
- no write permission ( see:
“
mbAc
” parameter)
A0h
- exceed of upper border of input range
60h
- exceed of lower border of input range
A0h and 60h codes can appear only during reg. 01h is reading by 03h function (read of
a single register).
Содержание PD96
Страница 14: ...User manual for meter with U I input PD96 14...
Страница 40: ...User manual for meter with U I input PD96 40...
Страница 49: ...User manual for meter with U I input PD96 49...
Страница 50: ...User manual for meter with U I input PD96 50...
Страница 55: ...User manual for meter with U I input PD96 55...
Страница 56: ...User manual for meter with U I input PD96 56...