Test signal. Press the set button, color bar appeared on the screen
and press any key to return to menu(SK- D385IR/M843 only)
2. How to use the jog lever
3. How to control through RS- 485 communication
4. Cable array o
①
ENTER :
②
UP,
③
DOWN
④
LEFT,
⑤
RIGHT
⑥
EXT- VIDEO
ㆍ
Push the lever : Used to access the menu and confirm selection.
ㆍ
Push the lever for one second : Used to return to previous menu
from the motion detection setting section or privacy mask setting
section.
: Used to move the cursor to up or down.
: Used to move the cursor to leftor right and change
the value.
: Extra video output terminal for installation.
Plug your test monitor in hear. The cable is option.
ch the camera with controller's ID, baudrate and protocol
2) Up, Down, Left and right of Jog lever is same as Up, Down, Left
and right of RS- 485 controller
3) Enter of Jog lever is the same as menu key or IRIS open key of
RS - 485 controller
4) Return to previous menu from motion detection setting section and
privacy mask setting section : Iris close or Iris open for a few second.
Or press the button as Up
1) No impact & motion alarm type
2) Built- in impact & motion alarm type
(option)
( ption)
1) Mat
Right
Down
Leftsuccessively
5
2
4
3
1
6
E : ORANGE(RX +)
F : WHITE(RX - )
A : BLUE(MOTION)
B : BLACK(GND)
C : GREEN(IMPACT)
D : BLACK(GND)
E : ORANGE(RX +)
F : WHITE(RX - )
MOTION ALARM
GND
IMPACT ALARM
GND
RX +
RX -
A
B
C
D
E
F
FUNCTION
ㆍ
If the camera detected motion when using Motion & Impact
function, outside line of motion alarm connect with GND(B).
ㆍ
If the camera detect impact, outsie line of impact alarm connect
with GND(D).Outputs of Motion & Impact are 'open collector'.
ㆍ
Max current & voltage are 200mA and 30V DC.
RS- 485A
RS- 485B
REMARK
No.
※
All specification is subject to change withoutnotic e to improve the quality.
Model No.
Image Sensor
TV Type
Sync. Type
Scanning System
Video Output
Gamma Characteristic
OSD
Motion Detection
Impact Detection(option)
White Balace
Privacy Zone
Day & Night
RS- 485 Protocol
S/N Ratio
Mirror
Backlight
Control Interface
Gain Control
Shutter
Test Illuminance Area
Current Consumption
LED
Operation Temp.
Preservation Temp.
Dimension
Weight
Resolution
Power Supply
Lens
Reverse polarity protection
Effective Pixel
Cell Size
Min. Illumination
NTSC / PAL
Internal
2:1 Interlace
1.0 Vp- p(Sync. Negative) Termination 75Ω ± 10 %
γ = 0.45(Adjustable)
Full OSD
ON / OFF Selectable(64 Zone)
ON / OFF Selectable(3 Step : LOW / MIDDLE / HIGH)
ATW / AWC / MANUAL
ON / OFF Selectable(4 Zone)
Electronic D&N(AUTO, COLOR, B/W)
PELC O- D&P
48dB over(AGC OFF)
ON / OFF
DWDR / BLC / HLC / OFF
YES
Extra Video connector for easy installation
Automatic(Adjustable)
1/60~ 1/100,000sec(NTSC), 1/50~ 1/100,000sec(PAL)
Average test illuminance by front view
Regulated 12V DC ± 10%
Max. 300mA(at 12V DC)
Fixed focal lens
IR LED 14EA
- 10
∼
50
℃
- 20
∼
60
℃
Ø 110 × 80(H)mm
Approx. 230g
700 TV- Line
1/3" SONY SUPER HAD CCD
Ⅱ
6.35
㎛
(H) X 7.4
㎛
(V)(NTSC)
6.5
㎛
(H) X 6.25
㎛
(V)(PAL)
768(H) X 494(V ) PIXEL(NTSC)
752(H) X 582(V) PIXEL(PAL)
0 Lux(15M Range) : LED ON
0.1Lux(F/1.2) : LED OFF
◐
SPECIFICATION
Color temperature 2500 ~ 9500°K
Adjust the Red or Blue values to shift the color
of the object
Move the camera lens toward to white paper
then press the set button to find the optimal
white balance for current environment
Auto day&night switching mode
Fixed at color(LED OFF)
Fixed at B/W(LED ON)
Determines whether to transmitthe burst signal
or not in B/W mode
You can select brightness of illumination about
changing the day
↔
night mode
You can selectthe duration time aboutchaining
the day
↔
nightmode
IR LED OFF/ON and output level adjustable
When IR LED is turned on in B/W, the objects
can be clearly identified due to the function
that decreases screen saturation of objects
within a short distance.
Set a horizontal image inversion
Sharpness adjustable
Gamma adjustable
Determines whether to use the brightness com-
pensation of four lens' corners(LSC) or not
The LSC level selectable
Adjust Red tone of the image
Adjust Blue tone of the image
Determines whether to use the motion detection
function or not
No display on the screen though movement
is detected
The words 'MOTION' appear on the screen
when movement is detected
Motion detection area appear on the screen
when movement is detected
Motion detection sensitivity
Set the duration of outside alarm. If the way of
display is message, it means display time of
message
Determines whether to use impact detection
function or not and sensitivity setting
Set the duration of outside alarm and display
time of "IMPACT" message
Display each privacy mask or not. Press the
set button to move into the privacy mask
setting section, whenever you press the set
button, the mask color is changed. When the
mask color is red you can adjust the size by
up, down, left and right button. When the
mask color is blue you can set the position of
mask by up, down, leftand right button. Press
the setbutton for a few second to escape
Select mask color
Selectthe camera ID for RS- 485 communication
Select baud rate
Select protocol
Select language
Display the camera ID on the screen
ATW
MANUAL
AWC
↓
AUTO
COLOR
B&W
OFF, ON
85 ~ 170
50 ~ 135
3 ~ 15
OFF, ON
OFF, ON
0 ~ 50
OFF, ON
0 ~ 50
0 ~ 200
0 ~ 200
OFF, ON
NONE
MESSAGE
MASK
0 ~ 255
1 ~ 15
OFF, LOW,
MIDDLE, HIGH
1 ~ 15
OFF, ON
1 ~ 255
2400 ~ 9600
ENGLISH, …
OFF, ON
Press the set button to move into the motion detection area
section to setthe 64 areas. Press the set button for a few second
to move out
Press the set button to select all area
Press the set button to remove all area
AWB MODE
D&N MODE
LED LEVEL
DYNAMIC IR
MIRROR
SHARPNESS
GAMMA
LSC
R- Y GAIN
B- Y GAIN
MOTION
IMPACT
MASK
1, 2, 3, 4
CAM ID
BAUDRATE
PROTOCOL
LANGUAGE
BURST
DELAY TIME
LSC LEVEL
DISPLAY
SET
WINDOW
ALL SET
↓
SENSITIVITY
HOLD TIME
HOLD TIME
EDIT
POSITION
6. PRIVACY
MASK
7. COMMUNI-
CATION
10. EXIT
9. FACTORY
SET
5. MOTION &
IMPACT
4. IMAGE
ADJUST
3. DAY&NIGHT
PELCO- D, PELCO- P
MASK COLOR
NAME DISPLAY
BLACK, GRAY…
8. SPECIAL
2. WHITE
BALANCE
ALLCLE AR
↓
COLOR
B&W
B&W COLOR
→
→
OFF, LOW, MIDDLE, HIGH
PATT ERN
GE NERATOR
Press the set button to move into the name setting section. You
can choose the letter by using up and down button and move
next letter by using left and right button. Press the set button for
a few second to move out
Press the set button to move into the position setting section.
You can move the camera ID to your wanted position by using
up, down, left and right button
※
If you change the COMMUNICATION value through RS- 485, you might not
control the camera due to unmatched value(If your camera is out of working
due to above reason, change your controller's value or wait a few minute till
close the menu, it will be back to previous setting value)
To reset your camera to factory default condition
Notice : Lens, communication and language is not changed
Save the value and then restart
0.45, 0.6, 1, USER
Fixed focal lens or Vari- focal auto iris lens
In case of manual lens selection, adjust the
brightness
In case of DC lens selection, adjust the bright-
ness
Shutter speed auto adjustable
Select shutter speed manually
Determines that use the AGC function or not
and AGC level selectable(You can not use the
Auto D&N change mode when AGC is off)
Digital Wide Dynamic Range
BLC function
High Light Mask function
In case of AUTO mode, the function will off in
daytime and on at night
According to the threshold value, the camera
will recognize as High light or not.
LENS
E.SHUTTER
AGC
DWDR
BLC
HLC
BRIGHT
DC LEVEL
HLC THR
MANUAL, DC
0 ~ 100
0 ~ 20
AUTO
OFF, LOW,
MIDDLE, HIGH
OFF, ON
OFF, ON,
AUTO
0 ~ 100
1. EXPOSURE
1/60(1/50) ~ 1/100,000
Func tion
setting menu S elect menu
Contents
Sub menu
OFF, LOW, MIDDLE, HIGH
◐
FUNCTION SETTING
1. OSD menu structure
DOIRP3000F