background image

SZU06C1 Product Manual

SZU06C1 PM(Rev 1.0)

SZU06C1 ZIGBEE WIRELESS COMMUNICATION

MODULE

Product Manual

Содержание SZU06C1

Страница 1: ...SZU06C1 Product Manual SZU06C1 PM Rev 1 0 SZU06C1 ZIGBEE WIRELESS COMMUNICATION MODULE Product Manual ...

Страница 2: ...uction 11 5 2 Customized firmware 11 6 Absolute Maximum Ratings 12 6 1 Environmental characteristics 12 6 2 Recommended operating conditions 13 7 DC Electrical Characteristics 13 8 Digital IO Specifications 14 9 AC Electrical Characteristics 15 10 Physical Dimensions and Footprint 17 10 1 Physical Dimensions 17 10 2 Recommended Footprint 18 11 Soldering Temperature Time Profile for reflow solderin...

Страница 3: ...using precautions 21 13 3 Storage conditions 22 14 Packaging 23 14 1 Carrier tape 23 14 2 Reel 24 15 Ordering Information 25 16 Drawing of Product Label 25 17 Disclaimer 26 18 RoHS Declaration 26 19 Data Sheet Status 27 20 Reference Documents 28 21 Contact Information 28 ...

Страница 4: ...C Excellent anti interference ability Outstanding networking stability Support ZigBee alliance ZSE standard protocol family Compliant with ZigBee Metering Implementation Programme Great Britain Companion Specification GBCS Customized software development available upon special request RF Features Based on the Silicon Labs EFR32MG1 chip solution Frequency Range 2405MHz 2480MHz 250 Kbps data transmi...

Страница 5: ... research and development period of products and further speed up the marketing of the products 1 2 Hardware description SZU06C1 ZigBee wireless communication module is composed of the high performance and low power consumption RF chip EFR32MG1B232 from Silicon Labs 38 4MHz system clock crystal oscillator 32 768KHz monitoring clock oscillator and RF radio frequency front end matching circuit which...

Страница 6: ... information of antennae for tests is shown in the following table Type Product Manufacturer wavelength Impedan Gain Antenna W1010 Pulse Electronics 1 4 dipole 50Ω 2 0dBi Table 2 1 Approved Antennae When SZU06C1 ZigBee wireless communication module is embedded into an OEM product it is prohibited to declare that his OEM products comply with CE certification in the name of approved CE certification...

Страница 7: ...he competent authorities of the spectrum management of the relevant member state prior to four weeks that the products are put on the market Besides the equipment must be marked with warning symbol to draw the user s attention to the fact that it might not be legal to use the equipment in every member state For this reason we recommend that the European customers limit the output power to 10mW 10d...

Страница 8: ...If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit differ...

Страница 9: ...into your own product and requiring explosion protection please make sure that your product must meet the above explosion proof parameters and indicate Transceiver Module II 3G Ex ic IIC Gc or similar words outside the final product Name And Address Of Notified Body TÜV SÜD Product Service GmbH Zertifizierstellen Ridlerstraße 65 80339 MÜNCHEN GERMANY Number Of Notified Body 0123 Special conditions...

Страница 10: ...ircuits according EN 60079 11 and EN 60079 14 have to be taken into account 3 The maximum service temperature of the communication module when incorporated into apparatus is 40 C to 80 C When utilized at this service temperature a T4 temperature classification is suitable 4 The communication module shall be installed in an enclosure that provides a minimum ingress protection of IP20 ...

Страница 11: ...e in the following Table 3 1 All GND pins are directly connected with the module but for best RF performance each GND pin shall be connected to a complete ground externally Pin No Pin Name Chip Pin IO Characteristic Function Description 1 GND GND System GND 2 NC Float directly 3 NC Float directly 4 D0 PD13 RW General GPIO 5 D1 PD14 RW General GPIO 6 D2 PD15 RW General GPIO 7 RESETn RESETn System R...

Страница 12: ... TDO_SWO PF2 Test Data Out 23 TDI PF3 Test Data In 24 TMS_SWDIO PF1 Test Mode signal 25 NC Float directly 26 NC Float directly 27 D3 PC0 R RW General GPIO 28 D4 PC1 R RW General GPIO 29 NC Float directly 30 NC Float directly 31 GND GND System GND 32 VCC VCC System Power Supply see note 2 33 GND GND System GND Table 3 1 Description of SZU06C1 Pinout Notes Low level is adopted for system reset In ca...

Страница 13: ...on the EFR32MG1B232 has multiple sleep modes which makes it to be more adaptable to the ultra low power consumption system It only takes a few milliseconds for change between different power modes that further ensures the low power consumption of the equipment SZU06C1 wireless communication module provides 8 lines GPIO one UART communication interface two debug interface one is 2 wire SWD and the ...

Страница 14: ... Analog input impedance 20 kΩ Analog input voltage 2 1 3 3 3 9 V GPIO output voltage 0 3 3 9 V Real time clock frequency 32 768 kHz Table 4 1 SZU06C1 Interface Characteristics SZU06C1 ZigBee wireless communication module provides a U FL interface for attaching one external SMA antenna or a PCB antenna In order to obtain the module s optimal RF performance it is recommend to use the antenna and fee...

Страница 15: ...UART interface Each module has only 64 bit identifier stored in FLASH which is similar to the MAC address in PC And now our module can only act as an end device which is not equipped with wiring function so it can be going to sleep mode so the end device generally applies battery for power supply and also can send and receive data through the router of parent node An end device is also equipped wi...

Страница 16: ... soldering Table 6 1 Limit Parameter Notes The limit values given in Table 6 1 shall not be exceeded under any condition and exceeding any one of the limit values may cause permanent damage to the device 6 1 Environmental characteristics Parameter Symbol Absolute maximum ratings Unit Note ESD1 THHBM V 2 KV Description of human body mode circuit ESD2 THCDM V 500 V Description of charged device mode...

Страница 17: ...z DD OP C f Parameter Test condition Symbol Value Min Type Max Supply Voltage VD D 2 1V 3 3V 3 9V Supply Current IVDD 200mA Reset Ireset 2 1mA 3mA Hard reset reset t 1ms FLASH FLSH erase C erase 10000 Flash data retention t r e te n tio n 10years Page erase terase 20ms 40ms I rea d 3mA Write operation I w rite 3mA RX Current Receive enable IR X 13 7mA 14 2mA TX Current TX power 0dBm ITX 17mA 19mA ...

Страница 18: ...e Min Typ Max Logic0 input voltage IL V 0 3 VDD Logic1 input voltage IH V 0 7 VDD Logic0 input current Input voltage 0V IL I 0 1nA 30nA Logic1 input current Output voltage DD V IH I 0 1nA 50nA I O pin pullup resistors PU R 30kΩ 43kΩ 65kΩ I O pin pulldown resistors PD R 30kΩ 43kΩ 65kΩ Logic0 output voltage 3mA Output load current 4mA 3 OL V 0 2 VDD Logic0 output voltage 20mA Output load current 4mA...

Страница 19: ...ty level Interferer is reference signal at 1 channel spacing 33 75 dB Interferer is filtered reference signal at 1 channel spacing 52 5 dB 7 Low side adjacent channel rejection 1 PER Desired is reference signal at 3dB above reference sensitivity level Interferer is reference signal at 1 channel spacing 35 dB Interferer is filtered reference signal at 1 channel spacing 54 7 dB 8 Alternate channel r...

Страница 20: ... at lowest power setting 26dBm 28 27 26 dBm Table 8 1 RF Characteristics of SZU06C1 RF Transceiver Notes Reference sensitivity level is 85 dBm Filter is characterized as a symmetric band pass centered on the adjacent channel having a 3dB bandwidth of 4 6 MHz and stop band rejection better than 26 dB beyond 3 15 MHz from the adjacent carrier Channel Frequency center Channel Frequency center CH11 2 ...

Страница 21: ... Dimensions of SZU06C1 Parameter Parameter Description Parameter value W Module width 19mm L1 Module length 25mm A1 Distance between semi holes 1 27mm A2 Distance from semi hole to PCB 0 8mm A3 Distance from U FL center to PCB edge 3mm A4 Distance from U FL center to PCB edge 5 55mm Table 10 1 Physical Dimensions of SZU06C1 ...

Страница 22: ... ensure that the corresponding PCB of keep out area part in Fig 3 1shall have no any device running line or applied copper 4 You must also ensure that there is no exposed copper on your layout which may contact with the underside of the module 5 To get the best RF performance it is recommended that each GND pin shall be connected to a complete ground level 6 It is recommended to use multiple vias ...

Страница 23: ...e recommended temperature climbing speed shall be 2 s and not exceed 2 5 s at the preheat area Cooling The recommended temperature descent speed shall be 3 s and not exceed 4 s at the cooling area Maximum Reflow Cycles of the module twice The module must not be placed at the bottom of PCB board for reflow soldering if the module is placed at the bottom of PCB board for reflow soldering device insi...

Страница 24: ...The module is dropped from the height of 50cm to hard floor to carry out the test for 3 times 3 Heat cycle test Charged operation of module start temperature of cycle 25 40 30 minutes 85 30 minutes for 5 cycles between high and low temperature 4 Moisture test Module operates at the environment of 60 and 90 RH for 24 hours 5 Low temperature cold start test Module will be powered after placed in the...

Страница 25: ...ess temperature during use of the products is the major factor of shortening the life of the products Thus full consideration of the impacts of heat radiation shall be taken in the design or use of the products to ensure that the environment temperature of the products shall not exceed the maximum operable temperature 2 Otherwise it may cause the reduction of the product performance and damage the...

Страница 26: ...safe distance between it and human body must be greater than 20 centimeters 13 3 Storage conditions 1 SZU06C1 must not be stressed mechanically during storage 2 Performance characteristics of the module shall not be evaluated under the following environment and the storage under this environment may have a large impact on the performance of SZU06C1 such as RF performance Salty air or environment w...

Страница 27: ...SZU06C1 Product Manual SZU06C1 PM Rev 1 0 23 14 Packaging 14 1 Carrier tape Fig 14 1 Dimension of Carrier Tape Top View Fig 14 2 Diagram of Cover Tape Fig 14 3 Diagram of Empty pocket ...

Страница 28: ...SZU06C1 Product Manual SZU06C1 PM Rev 1 0 24 Fig 14 4 Orientation of SZU06C1 14 2 Reel Fig 14 5 Reel Dimensions Each reel will be packed in a electrostatic shielding bag ...

Страница 29: ...n EFR32MG1single chip solution U FL interface for connecting a SMA or PCB antenna 19mm 25mm 3 7mm Visible barrier free communication distance is 2500m 16 Drawing of Product Label Fig 15 1 SZU06C1 Product Label The label dimensions are 15 2mm 17mm and the label will withstand temperatures used during reflow soldering ...

Страница 30: ...to modify or improve the product company name and LOGO at any time without prior notice In addition Chengdu Diyue Technology Co Ltd does not convey any license under its patent rights or assume any responsibility for the use of the described product 18 RoHS Declaration Statement of compliance of SZU06C1 ZigBee wireless communication module to EU environmental protection Hereby we declare to our be...

Страница 31: ...centration of 0 01 by weight in homogeneous materials for Cadmium and cadmium compounds 19 Data Sheet Status In order to improve design performance and supply the best possible products to customers Chengdu Diyue Technology Co Ltd reserves the right to change the product specifications without notice Please download the latest product specifications provided by our company before initiating or com...

Страница 32: ...formation Website www cdiyue com Add 4 F Block A Gaofa Building No 6 Jiuxing Avenue High tech Zone Chengdu Tel 0086 28 85138368 Fax 0086 28 85189190 E mail public cdiyue com Sales In China Tel 0086 28 85106132 Fax 0086 28 85189190 E mail sales cdiyue com International sales Tel 0086 28 85327536 Fax 0086 28 85189190 E mail wsales cdiyue com ...