DIVERSITECH DD-2X4 Скачать руководство пользователя страница 1

Visit our Website for more information on this product

www.diversitech.ca

1200 55

th

 Avenue, Montreal, Quebec H8T 3J8

Tel:  1.800.361.3733  |  Fax: 1.514.631.9480  |   [email protected]

DD-2X4

Downdraft Table

Mini DD

Downdraft Table

Operation & Maintenance Manual

PORTABLE DOWNDRAFT TABLES

READ AND SAVE THESE INSTRUCTIONS

Содержание DD-2X4

Страница 1: ...t www diversitech ca 1200 55th Avenue Montreal Quebec H8T 3J8 Tel 1 800 361 3733 Fax 1 514 631 9480 info diversitech ca DD 2X4 Downdraft Table Mini DD Downdraft Table Operation Maintenance Manual PORTABLE DOWNDRAFT TABLES READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...fely 7 4 2 Controls 7 4 3 Pre Use Checklist 8 4 4 Principles of Operation 8 4 5 DD 2X4 Pulse Filter Cleaning System 8 SECTION 5 MAINTENANCE TROUBLESHOOTING 9 5 1 To Maintain this Product Safely 9 5 2 Tools Required 9 5 3 Routine Maintenance Schedule 10 5 4 Filter Replacement DD MINI 11 5 5 Filter Replacement DD 2X4 12 5 6 Troubleshooting Procedure 13 APPENDIX 1A ELECTRICAL DIAGRAM MANUAL 120 VAC S...

Страница 3: ...t until a qualified person has indicated it is safe to do so Never use or install equipment where the potential for combustible fumes or dusts are present without a fire explosion protection system If you are unsure if the product you purchased is correct for your application call Diversitech at 1 800 361 3733 Breathing smoke fumes or dusts produced in applications such as welding cutting grinding...

Страница 4: ...ter Reversible carbon canister afterfilter Plasma Cutting Kit Side Back Walls Metal Mesh Prefilter 2 Steel bar grating Slag collection baffle with gravel PLA DD 2X4 VOC DD 2X4 CAW MINI DD DD 2X4 WGD MINI DD DD 2X4 DD 2X4 MINI DD Model Motor H P Power Avg Airflow Pressure CFM Static Pressure in Avg Face Velocity FPM Cord Length in Noise 5ft dB Phase hz 120V amps 230V amps 460V amps 575V amps Portab...

Страница 5: ...r Media Filter Size Cleaning Method Filter Efficiency MINI DD Downdraft Tables S MINI 0003 30 Paper Pleated 20 x 25 x 2 Disposable MERV 8 S MINI 0017 HEPA 20 x 25 x 4 Disposable MERV 17 S MINI 0005 Metal Mesh Panel 20 x 25 x 2 Water DD 2X4 Downdraft Tables S 2X4 20NF Nanofiber 20 Cartridge Compressed Air MERV 15 S 2X4 20PT Spunbond Poly 20 Cartridge Air Water MERV 11 S CCX 50R Carbon 20 Canister R...

Страница 6: ...20R power receptacle See APPENDIX 1A Electrical Diagram for wiring instructions Electrical Connection for units requiring 3 phase 230 460 575V direct connection See APPENDIX 1B Electrical Diagram for wiring instructions Have a certified electrician install electrical connection according to local regulations All three power leads must be connected to L1 L2 and L3 on the contactor This unit must be...

Страница 7: ... use that complies with all safety instructions contained herein and SECTION 3 3 Selecting a Location Confirm installation of correct input power source compressed air and any special installation requirements in accordance with SECTION 3 3 Installation Look at the manufacturer s label located on the exterior of the unit and ensure the source is correctly sized in terms of Voltage and Amperes Prio...

Страница 8: ... product is designed to capture and clean smoke and dust from light medium duty welding soldering and grinding applications When operating air is drawn in through the table surface grating passes through spark arrestor baffling then through the table s filtration system and exhausted through the side exhaust This product consists of seven basic components 1 Protective table surface grating s 2 Mul...

Страница 9: ...tenance on this product Disconnect power before performing any maintenance on unit including filter inspection The input power to this unit is high voltage and touching any live electrical parts can cause fatal shocks or severe burns Do not touch live electrical parts Keep away from all mechanical moving parts including motor gears and other pinch points while operating Operating this unit causes ...

Страница 10: ...nspect and clean if necessary the cabinet interior and dust drawer slats Inspect Metal Mesh Prefilter for any holes or damage caused by hot sparks Metal Mesh Prefilter can be cleaned by either blowing out with compressed air or submerging and washing in warm soapy water As Required Replace Filter 1 Replace Filter see SECTION 5 4 Filter Replacement for instruction Every 12 months Inspect Basic Comp...

Страница 11: ...oading or accumulation of particles 2 Rips tears or warping of filter media 3 Decreased table performance due to excessive static build up To remove the filter follow this 8 step procedure 1 Unscrew knobs to open the cabinet door 2 Remove Metal Mesh Prefillter if applicable 3 Remove dirty filter 4 Inspect cabinet interior for debris 5 Insert clean replacement filter 6 Ensure airflow indicator poin...

Страница 12: ... you see 1 Overloading or accumulation of particles 2 Rips tears or warping of filter media 3 Decreased table performance due to excessive static build up To remove the filter follow this 8 step procedure 1 Open the cabinet door 2 Unscrew twist knob to release the filter 3 Slide filter out 4 Inspect cabinet interior for debris 5 Opendustdrawerand remove material 6 Insert clean replacement filter ...

Страница 13: ...reaches indicated level Check input water and probes Fill to indicated level if necessary CORRECT Air Flow Restricted Check clean pre filters Unit Operates Properly Call for Service 1 800 361 3733 support diversitech ca Call for Service 1 800 361 3733 support diversitech ca Call for Service 1 800 361 3733 support diversitech ca YES YES YES TOO LOW TOO HIGH YES YES NO NO NO 13 5 6 Troubleshooting P...

Страница 14: ...m values 1 5 HP 120v TEFC Motor 60 Hz 120 VAC 60 hz Power Supply Motor 14 120v Single Phase Power Disconnect power before performing any maintenance on unit including filter inspection The input power to this unit is high voltage and touching any live electrical parts can cause fatal shocks or severe burns Do not touch live electrical parts APPENDIX 1A ELECTRICAL DIAGRAM MANUAL ELECTRIC SHOCK HAZA...

Страница 15: ...P 230 460 575v TEFC Motor 3600 RPM 60 Hz 230 460 575v 60 hz Power Supply Motor 15 230 460 575v 3 Phase Power Disconnect power before performing any maintenance on unit including filter inspection The input power to this unit is high voltage and touching any live electrical parts can cause fatal shocks or severe burns Do not touch live electrical parts APPENDIX 1B ELECTRICAL DIAGRAM MANUAL ELECTRIC...

Страница 16: ...ocopied or otherwise reproduced as needed for management of maintenance records MANUFACTURER DIVERSITECH INC MODEL N DOWNDRAFT SERIAL N SERVICE LOCATION CONTROL N Date Description of Service Serviced By Location Comments Only use manufacturer approved replacement parts on this unit ...

Страница 17: ... TEFC Motor 115 1 60 S 2X4 030T2 3 0 HP TEFC Motor 230 3 60 S 2X4 030T4 3 0 HP TEFC Motor 460 3 60 S 2X4 030T5 3 0 HP TEFC Motor 575 3 60 Part Number Filter Media Filter Size Cleaning Method Filter Efficiency MINI DD Downdraft Tables S MINI 0003 30 Paper Pleated 20 x 25 x 2 Disposable MERV 8 S MINI 0017 HEPA 20 x 25 x 4 Disposable MERV 17 S MINI 0005 Metal Mesh Panel 20 x 25 x 2 Water DD 2X4 Downd...

Страница 18: ...e a sufficient gap to fit the wall between the cabinet and the washers Place one back wall and one side wall with the flange facing outwards between the cabinet and the washers While resting the wall edge on the hardware check for alignment of bolt holes Fasten bolt lock washer washer net on the vertical edge attaching one side wall to one back wall Repeat process to attach all walls Ensure hardwa...

Страница 19: ...19 NOTES ...

Страница 20: ...t is the receiver s responsibility to file any freight claims with the carrier for obvious or concealed damages Damaged shipments must be refused at time of receipt by consignee RETURN MATERIAL POLICY Prior to the return of material for whatever reason a return manufacturing authorization number RMA is required from the Diversitech customer service department This procedure is necessary for proper...

Отзывы: