22
IX. Clean and Maintenance
1
. General neutral liquid detergent and soft cloth can be used for the daily cleaning of the
steam room. Do not use the detergent containing the acetone or ammonia spirit. If there is
any sticky dirt on the tub surface caused by sealing, wipe it off gently with a piece of soft
cloth soaked with some gasoline.
2. Use 1500# waterproof abrasive paper dipped in water to grind the scratch (if any) on the
acrylic surface, and polish it after that with a piece of soft cloth applied with some toothpaste.
3. Wipe off the stains on the room surface with a piece of soft cloth soaked with the weak
acid detergent such as the heated lemon juice or vinegar.
4. Remove the impurities such as hairs at the steam nozzle or the opening for sterilization gas
immediately, to make such parts always unclogged.
5. Do not wipe the gilded or chrome-plated pieces often (keep them away from any organic
solvent)
Note: the silicone gas with acid may damage the electroplated surface.
6. Never clean the tub surface with any rough tool with a rough surface or any detergent
containing chemical solvents or grains.
7. Never hit or scrape the tub surface with a blunt object or a cutting tool.
8. Ask the professional to remove the deposits in the steam generator after a certain times of
thermal circulation.
9. Drain off the remaining water in the steam generator each time after use to prolong its
service life.
10.Make a test to check the leakage protection performance of the leakage switch once a
month (the leakage switch is of proper performance as it trips when the test key on the
leakage protection plug is pressed. Press RESET to switch on the power supply again).
11. Check the power wires, switches and sockets often, to see if they are damaged by the
mice, insects or ants and cause the unnecessary loss.
12. Check the water pipe and drainage pipe often to see if there is any breakage or bending
causing the inconvenience in use. Always keep the drainage pipeline unblocked.
13. Reverted storage or piled storage of this product is not permitted. Keep it away from any
organic solvent such as the formic acid and formaldehyde.
14. Handle the product with care, and avoid any heavy pressure, mechanical hit and strong
vibration.
15. Keep the surroundings dry and ventilated without any corrosive gas for the steam room
idling for a long time, and cut off the water supply.
We reserve the rights to modify and change the relevant parameters and to increase or
decrease the sizes and models and configurations of the product. In case of any problem,
please call the dealer.