SK750/SK755 Operator’s Manual
Prepare - 36
Connect Attachment
CMW
Connect Attachment
Attachment
1.
Position attachment on level surface with enough
space behind it to accommodate unit.
2.
Ensure that lock pin handles (shown) on mount
plate are turned away from center of attachment.
3.
Start engine.
4.
Tilt mount plate (2) forward.
5.
Position mount plate in the upper lip of the receiver
plate (1) on attachment.
6.
Raise lift arms while tilting back mount plate.
7.
Turn ignition switch off and remove key.
8.
Rotate lock pin handles toward center of mount plate
to secure attachment to lift plate.
NOTICE:
Use only Ditch Witch-approved attachments. Attachments can change the stability and
operating characteristics of the unit.
IMPORTANT:
Before connecting attachment to unit,
ensure that mount and receiver plates are free of dirt
and debris.
IMPORTANT:
Attachment should be raised
enough to clear the ground. Mount plate
should be tilted back fully.
Incorrect procedures could result in death, injury, or property damage.
Learn to use equipment correctly.
To help avoid injury:
Ensure proper connection by verifying that bottoms of lock pins are
visible under attachment receiver plate (shown).
t05om022c.eps
t05om026c.eps
1
2
t05om027c.eps
Содержание SK750
Страница 1: ...SK750 SK755 Operator s Manual 053 2570 Issue 1 0 Original Translation CMW...
Страница 11: ...Contents 11 SK750 SK755 Operator s Manual CMW...
Страница 21: ...Safety 21 SK750 SK755 Operator s Manual Emergency Procedures CMW...
Страница 38: ...SK750 SK755 Operator s Manual Drive 38 CMW Drive Chapter Contents Start Unit 39 Drive 39 Shut Down 41...
Страница 49: ...Transport 49 SK750 SK755 Operator s Manual Tow CMW...
Страница 73: ...Service 73 SK750 SK755 Operator s Manual As Needed CMW...
Страница 80: ......
Страница 81: ......
Страница 82: ...SK750 SK755 Operator s Manual Service Record 82 CMW Service Record Service Performed Date Hours...
Страница 83: ...CMW Service Record 83 SK750 SK755 Operator s Manual Service Performed Date Hours...