1. Safety

3

1.1 Warnings, Cautions and Notes

3

1.2 General Warning

3

1.3 Fire Risk

3

1.4 Electric Shock Risk

3

1.5 Chemical Risk

3

1.6 Do’s

4

1.7 Do Not’s

4

2. Delivery and Storage

4

2.1 Receiving Inspection

4

2.2 Storage

4

2.3 Unpacking and Handling

5

3. Installation and Commissioning

5

3.1 Tools

5

3.2 Battery Location

5

3.3 Racks and Mechanical Stability

5

3.4 Parallel Connections

5

3.5 Series Connections

6

3.6 Series/Parallel Connections

6

3.7 Electrical Connections

6

4. Operation

6

4.1 Charging

7

4.1.1 Charge Curve

7

4.1.2 Commissioning Charge

8

4.2 Discharging

8

4.3 Temperature  Limits

8

4.4 Charge Current Limits

9

5. Battery Maintenance

9

6. Faults

9

7.   Transport

9

8. Recycling

9

9. Troubleshooting and Frequently Asked Questions

9

Operating Manual

DRY CELL  

BATTERY BLOCKS

 #4 -13511 Crestwood Place, Richmond, BC, V6V 2E9, Canada            + 1.778.776.3288           [email protected]

discoverbattery.com

Содержание DRY CELL

Страница 1: ...Stability 5 3 4 Parallel Connections 5 3 5 Series Connections 6 3 6 Series Parallel Connections 6 3 7 Electrical Connections 6 4 Operation 6 4 1 Charging 7 4 1 1 Charge Curve 7 4 1 2 Commissioning Ch...

Страница 2: ...rtain configuration installations service and operating tasks should only be performed by qualified personnel in consultation with local utilities and or authorized dealers Qualified personnel should...

Страница 3: ...l information concerning important procedures and features of the battery Read all the instructions before installation operation and maintenance This product must be recycled and is made of recycled...

Страница 4: ...for integrity and electrolyte leakage Record receipt date and inspection data results and notify your servicing dealer of any damage Take photographs if necessary 2 2 Storage Store in a dry clean vent...

Страница 5: ...atteries Be sure to provide adequate space and lighting for inspection maintenance testing and battery replacement Space should also be provided to allow the operation of lifting equipment and for tak...

Страница 6: ...nected in the correct polarity If the battery circuit has a disconnect open the disconnect to isolate battery Check that all contact surfaces are clean If required clean poles terminals with a brass b...

Страница 7: ...oat charge recharge can be terminated based on time this will need to be determined as it will vary with depth of discharge and charge current or percentage recharge 105 108 NOTE Acceptable charging A...

Страница 8: ...its With traditional stationary and renewable energy systems Depth of Discharge DOD is set to operate between 20 and 50 to maximize the life of the batteries By default this may be set by power conver...

Страница 9: ...following Inspect racks cabinets for corrosion or loss of integrity Check record if ventilation is sufficient Check record battery room temperature Check battery for cracks Check ground connections 6...

Страница 10: ...K This is often an indication of sulphated batteries which can be confirmed by completing a load test An increase in Absorption time may be necessary to sufficiently charge the battery to full SOC WHY...

Страница 11: ...d prior to storage The self discharge rate of fully charged batteries is very low in these conditions and they will not require charging for many months However if your batteries do freeze they may no...