Clocking
The clock source can be either set to MADI input or
AES input. It is adjusted in the menu (scaling factor)
see „System Menu“ on page 45.
Clocking to MADI
If both MADI inputs are locked an automatic
changeover to the other MADI input will occur once
the selected input looses its signal.
Selection pattern: the MADI input that locks first will
be used as sync and input source for conversion
Clocking to AES
Selection pattern: lowest AES input port detecting a
valid signal, if no valid signal is present the next input
is used.
Due to the selection pattern (‘lowest AES input’) a
change of the AES input signal condition may result
in a different clock source.