DirectOut Technologies D.O.TEC M.1k2 Скачать руководство пользователя страница 1

M.1K2

Hardware Guide

Version 1.3

Содержание D.O.TEC M.1k2

Страница 1: ...M 1K2 Hardware Guide Version 1 3...

Страница 2: ...uaranteed that all product names products trademarks requisitions regulations guidelines speci cations and norms are free from trade mark rights of third parties All entries in this document have been...

Страница 3: ...pdates 10 Conditions of Warranty 10 Intended Operation 10 Conformity Certi cates 11 Contact 11 Contents 12 CHAPTER 3 Installation 13 Installing the Device 13 Network integration 16 CHAPTER 4 Operation...

Страница 4: ...1k2 Hardware Guide Version 1 3 Appendix C Installing Replacing I O modules 28 Modules 29 Appendix D How to Network 30 Appendix E Firmware Update Instruction 32 Appendix F USB Serial Driver Installati...

Страница 5: ...online help within the gui Use the Table of Contents at the beginning of the manual or Index Directory at the end of the document to locate help on a particular topic You can access more information a...

Страница 6: ...ple rates Port redundancy may be applied to have a spare signal that will be used when an input signal breaks Two extra matrices may route serial data and MIDI data that is embedded into the MADI sign...

Страница 7: ...P v1 v2 Device Mirroring Doppelgaenger Mode Control Plug Ins Telnet Pro Bel SWP 08 network and serial MIDI Jupiter JSON USB Port USB 2 0 port for virtual COM port RS 232 Power Supply This device is eq...

Страница 8: ...with the system Only supply electrical interfaces with the voltages and signals described in these instructions Do not use the device at extreme temperatures Proper operation can only be guaranteed be...

Страница 9: ...he person as quickly as possible from the electric power source as follows Switch off the equipment Unplug or disconnect the mains cable Move the person away from the power source by using dry insulat...

Страница 10: ...ed Conditions of Warranty This unit has been designed and examined carefully by the manufacturer and complies with actual norms and directives Warranty is granted by DirectOut GmbH over the period of...

Страница 11: ...the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC WEEE Directive on Waste Electrical and Electronic Equipment Due to the directive 2002 96 E...

Страница 12: ...ardware Guide To complete the delivery please download from the M 1K2 product page on the DirectOut website www directout eu USB Serial driver latest firmware Three different types of I O modules are...

Страница 13: ...and a maximum relative humidity of 80 non condensing Ensure that the unit has suf cient air circulation for cooling CHAPTER 3 Installation Installing the Device 1 Open the packaging and check that the...

Страница 14: ...rn on the power switch and check the status of the PSU leds on the front panel 6 Network integration of the controller online wizard for initial setup of the network connection see Network integration...

Страница 15: ...ease_map pdf Keep any packaging in order to protect the device should it need to be dispatched for service 8 Optional Connect a USB cable to the USB port for use of the virtual com port This requires...

Страница 16: ...gs required standard network cable e g CAT5 Installation 1 Connect M 1K2 with your computer using a standard network cable e g CAT5 WARNING The network interface does not comply the requirements of IE...

Страница 17: ...oller The online wizard will open automatically and guide you through all necessary steps NOTE Following you may want to restore the network settings of your computer to the original values 5 After se...

Страница 18: ...l The control on the right of the front panel indicates the power supply Power switches are on the back panel PSU 1 PSU 2 rear 2 Switches Enable disable power supply PSU 1 PSU 2 rear C13 socket Connec...

Страница 19: ...26 STATE LED green indicates current system state LED ON controller is idle normal operation LED heartbeat controller is idle normal operation LED blinking once per second factory default network set...

Страница 20: ...nect RS 422 or RS 485 signal here Observe the correct pin assignment For safe operation lock the connection using the jack bolts GPO DSUB 9 socket female Connect GPO signals here Observe the correct p...

Страница 21: ...ard is detected automatically WCK IN 1 x BNC socket coaxial Connect word clock signal here WCK OUT 2 x BNC socket coaxial Connect here to receive word clock output signal The left socket provides the...

Страница 22: ...a standard CAT5 cable for connection with ethernet network 10 100 MBit s USB USB socket 2 0 USB connection for virtual serial port Requires a standard USB cable Type B NOTE To use the USB port as vir...

Страница 23: ...the device is connected to the power supply and that the socket is working Defective fuses must be exchanged by quali ed service personal only Optical port does not work Optic is dirty Use an air supp...

Страница 24: ...ly Environmental Conditions Operating temperature 5 C up to 45 C Relative humidity 10 80 non condensing MADI Port coaxial 16 x BNC socket 8 x input 8 x output Impedance 75 0 3 V up to 0 6 V peak to pe...

Страница 25: ...75 impedance input Termination 75 switchable MIDI 2 x DIN socket input output Serial Communication RS 232 RS 422 RS 485 General Purpose Output GPO 4 x Avago ASSR 1411 S optical MOSFETs up to 60 V 600...

Страница 26: ...ess the device via the initial IP address 10 0 0 24 The LED STATE indicates the operating condition LED Operating Condition Constant on The controller is idle normal operation Heartbeat The controller...

Страница 27: ...S 485 signals and bitrates of 9600 19200 38400 and 115200 bps PIN Signal 1 GND 2 RS 422 RX 3 RS 422 TX RS 485 RX 4 GND 5 6 GND 7 RS 422 RX 8 RS 422 TX RS 485 RX 9 GPO M 1K2 has four GPOs which can be...

Страница 28: ...use of an antistatic wrist strap for the handling of parts that are susceptible to electrical discharge 1 Remove all cables from the device 2 Loose both phillips screws at the left and right side of t...

Страница 29: ...page 29 of 44 M 1k2 Hardware Guide Version 1 3 Appendix C Installing Replacing I O modules Modules BNC Module coaxial SC Module optical SFP Module empty cages...

Страница 30: ...en two devices only Has IP address Gateway DHCP Dynamic host configuration protocol It is used to assign address parameters automatically to devices that are connected to a DHCP server Network router...

Страница 31: ...are a need it is helpful to set up a network manually Example 1 Peer to Peer The devices are connected directly This setup may be used at initial operation of the M 1K2 Example 2 Network with router...

Страница 32: ...commended that you backup the configuration data of the device Configuration Backup Restore in the GUI before performing the firmware update procedure Installation 1 Download the update file M 1K2 Fir...

Страница 33: ...page 33 of 44 M 1k2 Hardware Guide Version 1 3 Appendix E Firmware Update Instruction...

Страница 34: ...econds Please read this carefully 6 Con rm the update with Begin update The update process may take several minutes While updating the device is not accessible and audio will not be processed After up...

Страница 35: ...35 of 44 M 1k2 Hardware Guide Version 1 3 Appendix E Firmware Update Instruction NOTE It is strongly recommended to clear the browser cache after the update to ensure proper browser behaviour at next...

Страница 36: ...t eu Driver details This driver m1k2 black usb inf provides access to the virtual COM port The driver works with the M 1K2 black panel version only Installation 1 Unpack the driver les into a temp dir...

Страница 37: ...x F USB Serial Driver Installation 5 Right click on M 1K2 and select Update Driver Software 6 Browse to the location where you downloaded and unpacked the driver and select the folder 7 Click Next A s...

Страница 38: ...Windows automatically Deinstallation To uninstall the driver the device must be connected to the computer To remove the USB Serial driver from your system please execute the following instructions 1...

Страница 39: ...Summary 7 Firmware Update 32 First Aid 9 Fuses 24 G GPO Pin assignments 27 I Intended Operation 10 M Modules 29 Installing Replacing 28 N Network 30 DHCP 30 DNS 30 Gateway 30 IP Adress 30 Network Mask...

Страница 40: ...page 40 of 44 M 1k2 Hardware Guide Version 1 3 Notes...

Страница 41: ...page 41 of 44 M 1k2 Hardware Guide Version 1 3 Notes...

Страница 42: ...page 42 of 44 M 1k2 Hardware Guide Version 1 3 Notes...

Страница 43: ...page 43 of 44 M 1k2 Hardware Guide Version 1 3 Notes...

Страница 44: ...DirectOut GmbH T 49 3727 5665 100 F 49 3727 5665 101 www directout eu Leipziger Strasse 32 09648 Mittweida Germany...

Отзывы: