background image

© 2005 Directed Electronics, Inc. Vista, CA 

N426V  07-05

NOTE:

This product is intended for installation by a professional installer only!

Any attempt to install this product by any person other than a trained professional
may result in severe damage to a vehicle’s electrical system and components.

335500HHVV

IInnssttaallllaattiioonn  GGuuiiddee

Содержание Viper 350HV

Страница 1: ...ded for installation by a professional installer only Any attempt to install this product by any person other than a trained professional may result in severe damage to a vehicle s electrical system a...

Страница 2: ...are all Trademarks or Registered Trademarks of Directed Electronics Inc The Bitwriter p n 998T requires chip version 1 4 or newer to program this unit w ww ww w d di ir re ec ct te ec ch hs s c co om...

Страница 3: ...ei iv ve er r L Le ea ar rn n R Ro ou ut ti in ne e 2 21 1 T Tr ra an ns sm mi it tt te er r C Co on nf fi ig gu ur ra at ti io on ns s 2 23 3 Standard Configuration 23 Expanded Configuration 23 D Di...

Страница 4: ...eases as soon as the system is disarmed The orange wire is pre wired to control the 8618 starter kill relay It can supply up to 500 mA of current NOTE If using the H1 1 ORANGE wire to activate an add...

Страница 5: ...Toyota Lexus BMW some Mitsubishi some Mazda and other models NOTE For parking light systems that draw 10 amps or more the jumper must be switched to a light flash output see the Programming Jumpers se...

Страница 6: ...c co on nd d t ti im me ed d output will send a signal for 30 seconds when channel three is pressed This output can be shut off during the 30 second period by pressing Channel 3 again This output can...

Страница 7: ...f H1 6 BLUE instant trigger input This input will respond to a negative input with an instant trigger It is ideal for hood and trunk pins and will report on Zone 1 It can also be used with Directed si...

Страница 8: ...ptable ground points It is recommended that all security components be grounded at the same location H1 9 YELLOW ignition input Connect this wire to the 12 volts ignition wire This wire is pre wired t...

Страница 9: ...ose This fuse protects the module itself H1 12 RED WHITE 200 mA channel 2 output When the system receives the code controlling channel 2 for longer than 1 5 seconds the RED WHITE will supply an output...

Страница 10: ...ht LED operates at 2 volt DC and plugs into the two pin WHITE port Make sure the LED wires are not shorted to ground as the LED will be damaged Multiple LED s can be used but they must be wired in ser...

Страница 11: ...functions For more infor mation please refer to the guide packaged with the programmer This port can also be used to interface with Directed Video components for on screen security system programming...

Страница 12: ...ensor does not work well when mounted firmly to metal we do not recommend screwing down the control module The full trigger of the on board shock sensor reports Zone 2 See Table of Zones section of th...

Страница 13: ...g Jumper Light Flash Jumper This jumper is used to determine the light flash output In the position the on board relay is enabled and the unit will output 12V on the WHITE wire H1 2 In the position th...

Страница 14: ...e number of steps they have been broken up into two menus It is possible to access and change any of the feature settings using the Valet Program switch However this process can be greatly simplified...

Страница 15: ...es corresponding to the feature you wish to change For example to access the third feature press and release the switch three times Then press the switch once more and HOLD it The siren will chirp the...

Страница 16: ...hen press it once more and HOLD it The siren would chirp seven times to confirm access to the seventh feature To select another menu 1 Press and HOLD the Valet Program switch 2 After three seconds the...

Страница 17: ...lse Double unlock pulse 2 9 Single lock pulse Double lock pulse 2 10 Channel 3 Validity Channel 3 latched latched reset with ignition 30 second timed second unlock output 2 11 Comfort Closure On 20 se...

Страница 18: ...isplay separate steps for ignition lock and ignition unlock They can be programmed on or off independently 1 4 ACTIVE PASSIVE LOCKING If passive arming is selected in step 1 1 then the system can be p...

Страница 19: ...ve and the sensors are bypassed The door triggers will remain active If programmed to the Vehicle Recovery System VRS setting VRS will be activated 1 10 CODE HOPPING ON OFF The system uses a mathemati...

Страница 20: ...trigger is programmed off the full siren output will occur the moment the door is opened 2 5 VALET PULSE COUNT ONE TO FIVE PULSES The system can be programmed to count the number presses of the valet...

Страница 21: ...e windows when the system is armed A 20 second output starts 200mS after the last lock pulse The Comfort Closure output will be canceled if the unlock button is pressed If programmed the lock output w...

Страница 22: ...6 are used to assign the arm disarm and panic functions to separate buttons on the remote control Teaching a button to Channel 5 or Channel 1 erases some information about that remote from memory and...

Страница 23: ...Auto Learn functions in the Transmitter Receiver Learn Routine Standard Configuration When programmed for standard configuration the transmitter buttons are assigned to the following functions operate...

Страница 24: ...cannot be accessed from a standard configuration transmitter Diagnostics The system s microprocessor monitors and reports all active and violated zones when arming and disarming LED flashes indicate t...

Страница 25: ...k pins 2 On board shock sensor Heavy impact detected by the on board shock sensor 3 Two stage progresses from Door switch circuit H1 5 GREEN or H1 7 VIOLET warning to full alarm 4 Multiplexed Input BL...

Страница 26: ...urity Arming Multi Level Security arming allows the operator to select which inputs and sensors are active during a particular arming cycle For a full description of Multi Level Security Arming operat...

Страница 27: ...tion key on and off to clear the NPC from memory and then retest the shock sensor For a detailed description of NPC see Owner s Guide Door input does not immediately trigger full alarm Instead I hear...

Страница 28: ...cating the sensor can often solve this problem If the LED indicates that the door caused the trigger you may have programmed the progressive door trigger off See Feature 2 4 in the Feature Description...

Страница 29: ...2005 Directed Electronics Inc all rights reserved 29 Wiring Quick Reference Guide...

Отзывы: