35
Multi-Level Security Arming
Multi-Level Security arming allows the operator to select which inputs and sensors are active during
a particular arming cycle. For a full description of Multi-Level Security Arming operation for testing
purposes refer to the owner's manual.
Nuisance Prevention
®
Circuitry
Nuisance Prevention Circuitry bypasses any zone that triggers the system more than three times
within a one-hour period. For a full description of NPC operations refer to the owner's manual.
Rapid Resume Logic
Rapid Resume Logic ensures that the when the system is powered up it will return to the same state
it was in when power is disconnected. For a full description of Rapid Resume Logic refer to the
owner's manual.
IMPORTANT! When testing the systems sensor and trigger inputs reset NPC by
turning on the ignition after every third system trigger.
LED FLASHES
SHUTDOWN MODE
One
System timed out
Two
Over-rev shutdown
Three
Low or no RPM
Four
Transmitter Shutdown (or optional push-button)
Six
(-) Shutdown (H3/3 GRAY) or (+) Shutdown (H3/4 BROWN)
Seven
(-) Neutral safety shutdown (H3/6 BLACK/WHITE)
Eight
Wait-to-start timed out