background image

Direct Supply

®

PACKAGED TERMINAL AIR 

CONDITIONER/HEAT PUMP

Please keep and refer to this Owner’s Manual.

Owner’s Manual

1-800-634-7328

  

DirectSupply.com

Thank you for purchasing a Direct Supply

®

 Packaged Terminal Air Conditioner/Heat Pump from Direct Supply Equipment 

& Furnishings

®

. Please read this entire guide carefully and keep it for future reference. This guide will provide you with 

instructions, warnings, warranty information and other important information about your Packaged Terminal Air Conditioner/
Heat Pump. Share this information with your housekeeping, nursing and maintenance staff to help ensure the Packaged 
Terminal Air Conditioner/Heat Pump is cared for properly.

Содержание E7822

Страница 1: ...rom Direct Supply Equipment Furnishings Please read this entire guide carefully and keep it for future reference This guide will provide you with instructions warnings warranty information and other i...

Страница 2: ...with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible...

Страница 3: ...WARNING Do not use a product you suspect is not functioning properly Immediately contact Direct Supply Equipment Furnishings CAUTION When the air filter is to be removed do not touch the metal parts...

Страница 4: ...hich is located on the side of the cabinet and behind the grille Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equ...

Страница 5: ...so indicated by a light on the plug head TEST RESET Plug in press RESET NOTE Some plugs have buttons on the top NOTES Do not use this device to turn the unit on or off Always make sure the RESET butto...

Страница 6: ...P MODELS ONLY If the room temperature is 8 F below the setpoint temperature the heat pump will shut off and the electric heater will turn on until the setpoint is reached HIGH TEMPERATURE PROTECTION I...

Страница 7: ...7827 E7835 E7828 E7836 E7829 E7837 G1250 PERFORMANCE DATA Cooling Btu 7200 6800 7200 9000 8800 9000 12000 11800 12000 14700 14500 14700 14700 14500 Cooling Watts 610 576 610 796 778 796 1142 1124 1142...

Страница 8: ...erature is not too low this function is off Automatic Quick Warm up heat pump models only If the room temperature falls to 8 F 4 5 C below the setpoint temperature the reverse cycle heat is shut off a...

Страница 9: ...e compressor cycles off 3 When frost builds up to the evaporator coils the unit will defrost automatically and the compressor will cycle off FAN Fan operation only without heating and cooling UP DOWN...

Страница 10: ...Cycle for Cooling S9 Used with some types of wall thermostats Used with other types of wall thermostats Try with switch in the UP position first If this doesn t work try again with the switch in the D...

Страница 11: ...llow the fan to operate in continuous or cycle modes while the unit is in heating and cooling mode CON Continuous Allows the fan to run continuously circulating air even when the temperature setting h...

Страница 12: ...ted around or under NEVER through the wall sleeve The wire should then be routed behind the front panel to the terminal connector NOTE Refer to thermostat installation instructions for details on inst...

Страница 13: ...connector is wired If low fan is desired wire the G output from the thermostat to LOW FAN on the unit s terminal block If high fan is desired wire the G output from the thermostat to HI FAN on the un...

Страница 14: ...ng sleeve remove all baffles from the rear grille prior to installation of the PTAC To avoid vibration and noise make sure the unit is installed securely and firmly When installing the sleeve make cer...

Страница 15: ...til firmly against front of wall sleeve and secure with four screws and washers supplied in the SLEEVE ASSEMBLY through the unit flange holes See Fig 7 and Fig 8 Vent control lever Vent open Vent clos...

Страница 16: ...he unit The most important thing you can do to maintain unit efficiency is to clean the filters once every two weeks as required Clogged filters reduce cooling heating and airflow Keeping filters clea...

Страница 17: ...ormal during operation of unit Water Dripping Outside If a drain kit has not been installed condensation runoff during hot and humid weather is normal See Note 2 If a drain kit has been installed and...

Страница 18: ...Supply PTAC Extruded Architectural Grill C9782 Direct Supply PTAC Drain Kit C9783 Direct Supply PTAC Air Filter E7838 Sub Base Assembly for Direct Supply PTAC Units 265V 30 Amp Units E7839 Sub Base As...

Страница 19: ...have other rights which vary from state to state Please note that our limited warranty period begins when we ship the product to you The limited warranty period and our obligations under the warranty...

Страница 20: ...by Direct Supply Manufacturing Inc 6635 N Industrial Road Milwaukee WI 53223 2015 2018 Direct Supply Manufacturing Inc All Rights Reserved Direct Supply and all associated logos are the registered tra...