8.4.4 Saliva ejector
Saliva ejector is activated automatically after withdrawal from a holder. If the output is
insufficient, check and clean the sieve. See Chapter 10. Cleaning and Disinfecting for details.
8.4.5 Spittoon block configuration
Large and small aspirators
Aspirator activates immediately after withdrawal from the holder. To turn the aspirator off place
it back in the holder. To control the suction, slide the regulating flap on the aspirator up or down (when the regulating
flap is in the lowest position, suction is shut down). It is recommended to rinse both aspirators with 100 ml of water after
each patient. Inside the aspirator there is the sieve which needs to be cleaned at least once a day (see Chapter 10
cleaning and disinfection).
Polymerizing lamp
Polymerizing lamp activates immediately after withdrawal from the holder. Please, consult accompanying instructions
before using the lamp.
Intraoral camera
The camera serves to provide better visualization during the dental treatment but not to establish final diagnosis.
Camera consists of:
•
holder
•
connection - connector
•
camera
Caution
The product must be protected against water. Keep it dry.
8.5 Operating the dental chair
Chair can be controlled either from the:
•
control panel or
•
with a multi-function foot controller (UNO/NOK)
Basic movements are controlled by the chair move buttons.
.
To bring the chair into entry/exit position press the quick key
.
To get the chair to rinsing position, press key
.
For programming or activating previously saved chair positions, use button
.
For more detailed information, please, refer to DM20 or DE20 Instructions for Use.
While working with a handpiece, controlled with a foot controller, the safety block function is on. The dental chair
is protected from any accidental movement caused by pressing the buttons on the foot controller or on the
control panel.
8.6 Programming of the chair
8.6.1 Writing-in of the program position
Use these keys
to move the chair to the desired position.
To save the position use following key:
. Release the key and press this key
within five seconds; to assign a
hot-key for the position, press one of the following keys
within the next five seconds, otherwise
your custom settings will not be saved (factory settings will be recovered).
If it happens, that the chair has moved during programming of chair positions (while pressing buttons