FAULT FINDING
FAULT
REMEDY
1. The engine does not start
The main current is not connected.
Switch on the main switch and activate the system
by depressing the pedal switch (UCB) or by
pressing the activation button (LCB).
Lights flash on all control system buttons. Light
in the LCB emergency stop -button is off. The
machine is in emergency stop -mode.
Check that all emergency stop -buttons are up on
all control stations. Try to re-start the engine.
The engine starts and the display blacks out for
a moment.
Check the battery voltage
The following text appears on the display:
WATER TEMP: HIGH.
Let the engine cool down. Check the coolant level
and the air flow to the cooler.
Fuel tank is empty. The following text appears
on the display: FUEL LEVEL: LOW
Refuel and bleed the fuel supply system.
2. The engine starts but stops for a while
The following text appears on the display: OIL
PRESS LOW.
Check the engine oil level.
3. None of the stabilisers move
The boom system is not in transport position.
54.1676
54.1675
54.1674
54.1673
KG
If the stabilisers are up, check the red
signal light on the retraction button.
If the light flashes, the relescope is not
fully in. Retract the telescope by pushing
the button.
If the stabilisers are down, check that the telescope
is in, boom and articulated arms are down and the
turning device is aligned with the chassis.
4. Disturbance of platform movements - only some of the movements are operational
The stabilisers are not pressed down properly.
Make sure that all the stabilisers are steadily
supported on the ground. Check the stabiliser
status from the display.
The chassis is not levelled within the allowed
inclination limit. Inclination warning light is
flashing.
54.1676
54.1675
54.1674
54.1673
KG
Level the chassis within the allowed
limit. Check the inclination angle from
the display.
Overloading of the boom has occurred.
Overload warning light is flashing.
54.1676
54.1675
54.1674
54.1673
KG
Return to the outreach area allowed for
the load by retracting the telescope.
Reduce load on the platform.
Telescope out -movement is not working.
Telescope out -movement is prevented when the
boom is on the support. Lift the boom from the
support and try again.
Содержание DINO 280RXT
Страница 2: ...2 Operating instructions DINO 280RXT...
Страница 6: ...6 Operating instructions DINO 280RXT...
Страница 11: ...11 2 2 REACH DIAGRAM 120 kg 230 kg...
Страница 63: ...63 NOTES...
Страница 71: ...71 BLANK...
Страница 73: ...73 NOTES...
Страница 74: ...74 Operating instructions DINO 280RXT NOTES...