DOSAGE
47
If during the dosage the mains voltage is cut off, when it is restored, the instrument will turn on
automatically into PAUSE; press the
button to continue with the interrupted dosage. The
dosage now restarts from the condition in which it was in, when it turned off.
In the PAUSE condition it is possible to access the USER MENU function "Repeat dosage cycles", in which it
is possible to change the number of the cycles.
It is possible to enter in Repeat dosage cycles step only in weights formula mode.
It is also possible to turn off the instrument by pressing at length the C key.
6.13.3
Dosage cycle reset
To cancel the dosage cycle in execution, keep closed the pause input(IN.2) for about 3 seconds or push
button. The "RESET DOSAGE" message will be shown on the display.
By carrying out this operation the indicator cancels the dosage and the GROSS weight on the scale plate
appears on the display. By cancelling the dosage under way, if the material has been dosed, the production
of the single formula and the general total is increased.
To cancel a dosage during a repetition of the dosage cycles, one should carry out a reset (described
previously); the status bar will show "RESET DOSAGE"; after this, the instrument is in the WAIT FOR START
status: by giving a start command the number of executed dosages shown on the display is increased by 1,
and the dosage continues with the following cycle.
To cancel a set repetition of cycles, one should execute a reset in order to exit the dosage cycle: the
message “RESET DOSAGE” will appear for a few instants on the display and the instrument goes into the
WAIT FOR START status. At this point one should execute a further reset, which will cancel the set
repetitions.The number of repetitions is zeroed, returning into the 1 status.
NOTE: the reset does not work in the WAIT FOR START condition (except for when the number of
repetitions is cancelled).
6.13.4
Setting the number of consecutive repetitions of the active formula
It is possible to programme a series of automatic repetitions of the dosage cycles using a specific formula.
One should:
Push
button
Enter the number of repetitions to be executed (value which is between 0 and 999).
-
Formula Cycles = 0
infinite repetitions with manual start through the START button
-
Formula Cycles = 999
infinite repetitions with automatic start
-
Formula Cycles = n
executes n repetitions with automatic start
Confirm the number of set cycles by pressing the OK key.
DESCRIPTION OF THE FUNCTION:
The display will show the number of executed cycle repetitions, which will increase at the end of each
complete cycle, and the number of cycles to be executed.