7
Table 5.1 function description of display panel setting key
Note: description of display and setting key operation
(1) The parameter setting in this chapter refers to the operation on the display
panel produced by our company. Please refer to the instructions for touch screen
operation
(2) "Weighing display status" in this chapter refers to the default state that
no menu is entered after the instrument is powered on
(3) The key operations in this chapter are represented by square brackets and key
names, such as: [input], [Pxx]
If there is no special description, key operation refers to short press, if
it is long press, it will be marked, such as long press [FXX]
(3) The corresponding contents are shown in brackets in [[010]
(4) Display panel digital tube display comparison table
A B C D E F G H I J K L M N O P R S T U Y
A B C D E F G H I J K L M N O P R S T U Y
Table 5.2 comparison table of digital tube display on display panel
5.2 Introduction of instrument parameters
The instrument has two groups of parameters: f parameter and P parameter. The
meaning of f parameter is fixed, which is the internal working parameter and
operation item of the instrument. For details, see
Whether the
corresponding parameters of the instrument and the password are visible or not
are determined by the corresponding workflow of the instrument.
Long press the [FXX] key to enter the view and setting of the f parameter,
and long press the [Pxx] key to enter the view and setting of the P parameter.The
specific operation method is described in the following chapters.
5.3 Password control and permitted operation items
This instrument implements password control. After the instrument is powered
on, the initial state is no login.Some operations of the instrument can only be
carried out after logging in with the corresponding password. There are three
levels of passwords: user-1, user-2 and user-3.The corresponding functions can
be operated by logging in with different passwords. The authority levels of the
three levels of passwords are increased in turn,The operation items allowed to
log in with the password at this level are also increased in turn, as shown in
the following table:
seri
al
numb
er
Operation items
Login password level
No
login
user
admin
istra
tors
manufa
ctor
1
Zero and tare operation
√
√
√
√
2
View and modify unregulated P
parameters
√
√
√
√