Appendix 2 Command of Continuous Sending Mode
When the communication parameter F06 is set to 4,5,6,7, it is the continuous transmission
mode. At this time, F07 no longer represents the instrument address, but represents the
information content and format of continuous transmission. The time interval between two
consecutive strings of data is 35 ms.
The sending format is as follows:
parameter
F07
Format name
Content format
remarks
1
Top loose format
1
(STX)Aa±nnnnnnptttttteff(CHK)(ETX)
The return of a
command
2
Yaohua old D2+
format
=51.0700=51.0700
……
8 bytes per frame
3
/
4
TOLEDO standard
format
Without checksum
5
TOLEDO standard
format
With checksum
6
705 format
ST,GS,+0012.34,kg(CRLF)
US,GS,-002000,kg(CRLF)
7
Top loose format
2
(STX)AA
±
nnnnnnptttttteff(CHK)(ETX)
8
/
9
/
10
/
11
Taiwan Province
C-8500TS
UMC600 format
(STX)- 12.34KGM(CRLF)
12
XK3190-A9 mode
(STX)-002000PCC(ETX)
Yaohua
13
/
14
Hbwe2110 format
(STX)- 12.34G(ETX)
(STX)12.34M(ETX)
15
Yaohua new D2+
format
=51.07000=51.07000
……
9 bytes per frame
16
A8MD dynamic
table format
[7F7F7F7F7F02]npss111222
…
..xxxC
17
/
18
RI5000 format
(STX)- 12.34G(CRLF)
(STX) 12.34M(CRLF)
19
HB8212 format
(STX)- 12.34 kg GRM(CRLF)
(STX) 12.34 kg GR (CRLF)
Formosa plastics
20
EX2001 format
ST,GS,+0012.34kg(CRLF)
Similar to 1705