To wire through a wall switch:
1. Cut the wire to an appropriate
length.
2. Connect the L wire from the
unit to the live wire
from the
main power
through the
wall switch
, ensuring all live
connections are connected
with
a wire nut.
3. Connect the N wire from the
unit to the neutral wire from the
power supply with a wire nut.
Glass
Openings
4. Connect the G wire from the
unit to the ground wire from the
power supply with a wire nut
or
attach the grounding wire
to the cover with the provided
grounding screw, by placing the
wire in-between screw and lock
washer and tighten (Figure 3).
5. Ensure that all wires are secure
and do not protrude past the
flame panel, so as not to be
visible after final assembly.
6. Continue to the final assembly
instructions.